Storage and transport conditions

Temperature

 

 

–10°C to 40°C (14°F to 104°F)

Humidity

0% to 90%

Pressure

700 hPa to 1060 hPa

Accessories supplied

AC power cord (1) AC plug holder (1) Fuse (1)

Tally plate (1) (BVM-D20F1U/D20F1E/D20F1A only) 4:3 mask (1) (BVM-D20F1U/D20F1E/D20F1A only) Operation manual (1)

Quick reference (1)

Acquired safety regulations

UL1950, CSA No.950

FCC Class A, IC Class A

DHHS, DNHW

TÜV (EN60950)

CE, C-tick

Design and specifications are subject to change without notice.

Appendix 3 Chapter

Available Signal Formats

 

Total lines

Active

Frame

 

 

 

System

per frame

lines per

rate** (Hz)

Scanning format

Aspect

Standard

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

575/50I (PAL*)

625

575

25

2:1 interlace

16:9/4:3

ITU 601

 

 

 

 

 

 

 

480/60I (NTSC*)

525

483

30

2:1 interlace

16:9/4:3

ITU 601

 

 

 

 

 

 

 

575/50P

625

575

50

Progressive

16:9/4:3

 

 

 

 

 

 

 

480/60P

525

483

60

Progressive

16:9/4:3

SMPTE 293M

 

 

 

 

 

 

 

1080/48I

1125

1080

24

2:1 interlace

16:9

 

 

 

 

 

 

 

1080/50I

1125

1080

25

2:1 interlace

16:9

SMPTE 274M

 

 

 

 

 

 

 

1035/60I

1125

1035

30

2:1 interlace

16:9

BTA S-001B

 

 

 

 

 

 

 

1080/60I

1125

1080

30

2:1 interlace

16:9

SMPTE 274M/BTA S-001B

 

 

 

 

 

 

 

720/60P

750

720

60

Progressive

16:9

SMPTE 296M

 

 

 

 

 

 

 

* Available when the optional adaptor is installed. ** Also compatible with 1/1.001.