Menus 8 Chapter

Menu items in the 100s, relating to the control panels

Item number

Item name

Settings

 

 

 

121

FRAME PB MODE a)

Specify the frame mode for variable speed playback.

 

 

field: Field playback

 

 

frame: Frame playback. Compared to field playback, frame playback

 

 

gives still pictures with higher precision.

 

 

 

130

DISPLAY DIMMER CONTROL

Set the brightness of the audio level meters.

 

 

0 ... 6 ...7: Set in this range. 0 is the brightest, and 7 the dimmest.

 

 

 

131

AUDIO VOLUME

Select whether each of the ALL/CH-1, CH-2 to CH-4 adjustment knobs

 

 

on the control panel is effective to control the audio recording level and

 

 

playback level on each channel or the ALL/CH-1 adjustment knob alone

 

 

functions as a master control to control the audio level on all channels

 

 

together.

 

 

each: Each of the ALL/CH-1, CH-2 to CH-4 adjustment knobs is effective

 

 

to control each channel.

 

 

all: The ALL/CH-1 adjustment knob alone functions as a master control.

 

 

When “all” is selected, the ALL indicator to the right of the ALL/CH-1

 

 

adjustment knob lights up.

 

 

 

142

REPEAT MODE a)

Put the unit into repeat playback mode, or exit from repeat playback

 

 

mode.

 

 

off: Exits from repeat playback mode.

 

 

play: Puts the unit into repeat playback mode.

 

 

 

143

INDEX PICTURE POSITION

Select the frame of the clip to use as the thumbnail image (index picture)

 

 

when recording.

 

 

0sec to 10sec: Can be set in the range from 0 seconds (first frame of the

 

 

clip) to10 seconds, in units of 1 second.

 

 

 

a) This is supported from firmware version 1.4.

Menu items in the 200s, relating to the remote control interface

Item number

Item name

Settings

 

 

 

 

214

REMOTE INTERFACE

 

When the remote control switch is set to REMOTE, select the device from

 

 

 

which to remote-control this unit.

 

 

 

9PIN: Device connected to the REMOTE connector.

 

 

 

i.LNK (i.LINK): Device connected to the S400 (i.LINK) connector.

 

 

 

 

 

215

i.LINK MODE

 

Select the connection method for the S400 (i.LINK) connector.

 

 

 

 

 

 

AV/C: Connect with AV/C.

 

 

 

FAM (FAM (PC REMOTE)): Connect with FAM.

 

 

 

 

257

NETWORK ENABLE

 

Select the remote control switch positions which enable network

 

 

 

connections.

 

 

 

net (network): Only when the switch is set to “NETWORK.”

 

 

 

n&9P (network & remote(9PIN)): When the switch is set to

 

 

 

“NETWORK,” and when the switch is set to “REMOTE” and extended

 

 

 

menu item 214 is set to “9PIN.” a)

 

 

 

a) FTP connections can be made only when the device connected to the REMOTE

 

 

 

connector (D-sub 9 pin) is in stop mode. During FTP connections, the device connected

 

 

 

to the REMOTE connector cannot be used to control this unit.

 

 

 

 

258

LIVE LOGGING b)

 

Enable or disable the live logging function when using the PDZ-1 Proxy

 

 

 

Browsing Software.

 

 

 

off: Disable.

 

 

 

on: Enable.

 

 

 

 

 

 

 

 

Note

 

 

 

During

live logging, regardless of the settings of menu items 626 and

 

 

 

627, the internal time code generator always runs in free run mode. Time

 

 

 

code cannot be recorded in internal preset mode.

 

 

 

 

 

b) This is supported from firmware version 1.4.

 

 

 