Troubleshooting and Maintenance 9 Chapter

Message in time

Display

Description

Action

data display

condition a)

 

 

IMX50 Clip

on, limit

A recording, E-E display, or edit preset

To perform these operations on the disc,

IMX40 Clip

 

operation was attempted on a disc

change the setting of basic menu item 031.

IMX30 Clip

 

recorded in a format different from the

See 8-2-2 “Basic Menu Operations” (page

DVCAM Clip

 

setting of basic menu item 031

4CHx24 Clip

 

“RECORDING FORMAT.”

105) about how to change this setting.

8CHx16 Clip

 

 

 

 

 

 

 

REC INHI.!

on, limit

An attempt to save the current clip list

To perform these operations, cancel all of

 

 

was made while the REC INH indicator

the following write-protect settings.

 

 

was lit.

• Write Inhibit tab of the disc

 

 

 

• Setting of extended menu item 310 “REC

REC INHI.!

on, limit, off

An attempt to delete a clip was made

INHIBIT”

 

 

while the REC INH indicator was lit.

 

 

• Mismatch between the recorded

 

 

 

REC INHI.!

on, limit, off

An attempt to format a disc was made

sections of the disc and the setting of

 

 

while the REC INH indicator was lit.

 

 

basic menu item 031 “RECORDING

 

 

 

 

 

 

FORMAT”

 

 

 

 

No Clip!

on, limit

A playback or search button was

These operations are not possible.

 

 

pressed for a disc containing no

 

 

 

recorded clips.

 

 

 

 

 

No Clip!

on, limit, off

An attempt was made to delete a clip

 

 

 

from a disc containing no recorded clips.

 

 

 

 

 

Disc Top!

on

The PREV button was pressed while

 

 

 

stopped at the top of the disc, or an

 

 

 

attempt was made to perform a high-

 

 

 

speed reverse search.

 

 

 

 

 

Disc End!

on

The NEXT button was pressed while

 

 

 

stopped at the end of the disc, or an

 

 

 

attempt was made to perform a high-

 

 

 

speed forward search.

 

 

 

 

 

MAX # Files

on, limit, off

The number of files on the disc had

Insert a different disc with enough free

 

 

reached the upper limit (5000), or there

capacity.

 

 

was not enough capacity in the General

 

 

 

directory when an attempt was made to

 

 

 

record, display an E-E picture, record an

 

 

 

essence mark, or add a quick scene

 

 

 

selection sub clip.

 

 

 

 

 

Disc Full!

on, limit, off

An attempt was made to record or

 

 

 

display an E-E picture when there was

 

 

 

not enough free capacity on the disc, or

 

 

 

when the number of recorded clips had

 

 

 

reached the upper limit (300).

 

 

 

 

 

MAX# SB CLP

on, limit, off

An attempt was made to add a sub clip

These operations are not possible.

 

 

when the number of registered sub clips

 

 

 

had already reached the upper limit

 

 

 

(300) of the specifications of this unit.

 

 

 

 

 

CL OVER DUR

on, limit, off

An attempt was made to add a sub clip

 

 

 

when the total duration of sub clips in the

 

 

 

clip list had already reached the upper

 

 

 

limit (24 hours) of the specifications of

 

 

 

this unit.

 

 

 

 

 

Run Salvage

on, limit, off

An attempt was made to record, display

Try the operation again after executing the

 

 

an E-E picture, record an essence mark,

salvage function.

 

 

or add a quick scene selection sub clip

For details, see 3-5-7 “Handling of Discs

 

 

on a disc which requires clip recovery

 

 

(salvage).

When Recording Does Not End Normally

 

 

 

(Salvage Function)” (page 47).

 

 

 

 

CNT mode!

on

A time code or user bits preset operation

Try the operation again after selecting “TC”

 

 

was attempted with “COUNTER”

or “UB” with the COUNTER SELECT

 

 

selected by the COUNTER SELECT

button.

 

 

button.

 

 

 

 

 

138 9-3 Alarms