Note

The time zone is reset to the factory default when you execute the maintenance menu item “RESET ALL SETUP.” You will need to set it again. The date and time are not reset.

3-4Superimposed Text Information

The video signal output from the VIDEO OUT 2 (SUPER) connector or the SDI OUT 2 (SUPER) connector contains superimposed text information, including time code, menu settings, and alarm messages.

Adjusting the text display

You can adjust the position, size and type of the superimposed text using basic menu items 002, 003, 005, 009, 011, and 012.

For details, see 8-2-1 “Items in the Basic Setup Menu” (page 102).

Information displayed

1Type of time data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2Time code reader drop frame

 

 

 

 

 

 

 

mark (for 525 line mode only)

 

 

 

 

 

 

 

 

3Time code generator drop

 

 

 

 

 

 

 

 

 

 

frame mark (for 525 line

 

 

 

 

 

 

 

 

 

 

mode only)

 

 

 

Time data

 

 

 

 

 

4VITC field mark

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T C R

0 0 : 0 4 . 4 7 . 0 7 *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B 1

 

P L A Y

L O C K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7Playback condition

 

 

 

 

 

 

 

 

 

 

 

 

mark

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6Operation mode

 

 

 

 

 

 

 

 

 

 

 

 

 

5Menu setting states

 

 

 

 

 

 

 

Note

The display shown above corresponds to the factory default settings of the unit. You can change the type of information to be displayed in the lower line of the display by changing the setting of basic menu item 005

“DISPLAY INFORMATION SELECT.”

For details, see 8-2-1 “Items in the Basic Setup Menu” (page 102).