6.Command Specification

MODE SELECT

6.7.3.Data Compression Control Page (0Fh)

The drive supports the Data Compression Control Page which has the following format:

Table 6-45: Data Compression Control Page

Bit

7

6

 

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

0

PS (0)

Reserved

 

 

 

 

 

Page Code (0Fh)

 

 

1

 

 

 

 

 

Page Length (0Eh)

 

 

 

2

DCE

DCC (1)

 

 

 

 

 

Reserved

 

 

 

3

DDE

RED

(00h)

 

 

 

 

 

Reserved

 

 

4

(MSB)

 

 

 

 

Compression Algorithm (0003h)

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

(LSB)

8

(MSB)

 

 

 

Decompression Algorithm (0003h)

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

(LSB)

12

 

 

 

 

 

 

Reserved

 

 

 

13

 

 

 

 

 

 

Reserved

 

 

 

14

 

 

 

 

 

 

Reserved

 

 

 

15

 

 

 

 

 

 

Reserved

 

 

 

This page specifies the parameters for the control of the data compression capability of the drive.

DCE: A Data Compression Enable (DCE) bit of one indicates that data compression is enabled. When this bit is set, data sent to the device by the initiator will be processed using the selected compression algorithm before being written to the medium. A DCE bit of ZERO indicates that data compression is disabled.

DCC: A Data Compression Capable (DCC) bit of one indicates that the drive supports data compression and will process data sent to it for transferal to the medium using the selected compression algorithm when the DCE bit is one. A DCC bit of ZERO indicates that the device does not support data compression. This will be a non-changeable field. The SDX-1100V has the capability to decompress data and will set this bit to a one.

DDE: A Data Decompression Enable (DDE) bit of one indicates that data decompression is enabled. The SDX-1100V will always decompress the data. Setting this bit to ZERO has no effect.

RED: The Report Exception on Decompression (RED) field indicates the device’s response to a boundary condition caused by a change in the format of recorded data from:

uncompressed to compressed or compressed to uncompressed This field is not supported and will be always set to 00b.

Compression Algorithm: The compression algorithm field indicates the compression algorithm the drive will use to process data sent to it by the initiator (if the DCE bit is one).

The SDX-1100V supports the ALDC1 data compression algorithm which is identified by the value: 00 00 00 03h in the compression algorithm field. A value of ZERO will indicate that no compression algorithm is currently selected. Any other values in this field will cause the drive to return a CHECK CONDITION status the sense key will be set to ILLEGAL REQUEST.

Decompression Algorithm: For MODE SELECT the decompression algorithm field indicates the decompression algorithm selected by the initiator for use in subsequent decompression of data encountered on the medium.

The SDX-1100V can decompress data recorded with the ALDC1 algorithm therefore this field can be set to 00 00 00 03h. However, the SDX-1100V is capable of automatic recognition of the compression algorithm used to process the data encountered on the medium. Therefore, the drive will override the value in the decompression field (if is set to ZERO) for a subsequent read operation when ALDC1 compressed data is detected on the media.

For the MODE SENSE command, the decompression algorithm field reflects compression algorithm which was used to process the data most recently encountered on the medium, during a read operation.

A value of ZERO will indicate that the data encountered on the medium during the most recent read operation was uncompressed.