LOG SELECT

6.Command Specification

6.5.LOG SELECT 4Ch

Bit

7

 

 

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

Operation

Code (4Ch)

 

 

 

 

 

1

 

 

 

 

 

Reserved

 

 

 

 

PCR

 

SP (0)

2

 

PC

 

 

 

 

Reserved

 

 

 

 

3

 

 

 

 

 

 

 

Reserved

 

 

 

 

4

 

 

 

 

 

 

 

Reserved

 

 

 

 

5

 

 

 

 

 

 

 

Reserved

 

 

 

 

6

 

 

 

 

 

 

 

Reserved

 

 

 

 

7

(MSB)

 

 

 

 

 

Parameter List Length

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

9

 

 

 

 

 

 

 

Control

 

 

 

 

The LOG SELECT command provides a means for the initiator to manage statistical information maintained by the device about its own hardware or the installed media. This description will be read in conjunction with the description of the LOG SENSE command which follows it, to provide the reader with information about log page format, parameters and supported pages.

PCR: A Parameter Code Reset bit of one and a Parameter List Length of ZERO will cause ALL log pages which can be cleared, to be cleared. If this field is set and the Parameter List Length field is non-ZERO then the command will be terminated with a CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an ASC of INVALID FIELD IN CDB.

SP: The device does not have non-volatile RAM into which it may save parameters. Therefore, the Save Page bit is not supported by this device and will always be set to ZERO. If the SP bit is set, the command will be terminated with a CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an ASC of INVALID FIELD IN CDB.

PC: The Page Control field defines the type of parameter values to be selected:

Table 6-5: Page Control field values

Value

Description

00b

Current Threshold Values

01b

Current Cumulative Values

10b

Default Threshold Values

11b

Default Cumulative Values

If this field is set to 00b, 10b or 11b and the Parameter List Length field is non-0 then the command will be terminated with a CHECK CONDITION status with the sense key set to ILLEGAL REQUEST, and an ASC of INVALID FIELD IN CDB. This is because no modification of these log pages is permitted. For a description of command behavior if this field is set to 01b then see the description of the Parameter List Length field below.

If this field is set to 10b and the Parameter List length field is 0 then all Current Threshold Values will be reset to the Default Threshold Values. This is equivalent to no change as Threshold Values cannot be modified.

If this field is set to 11b and the Parameter List Length field is 0 then all Current Cumulative Values will be reset to the Default Cumulative Values. This is equivalent to all log pages which can be cleared.

Parameter List Length: This field specifies the length in bytes of the LOG SELECT parameter list that will be transferred from the initiator to the target during the DATA OUT phase. A parameter list length of ZERO indicates that no data will be transferred. This condition will not be considered as an error (see description of Parameter Code Reset and Page Control fields above). If this field is non-0 the Page Control field must be 01b.

SONY AIT-5 drive SDX-1100V series Ver.1.0

6-11

Page 65
Image 65