6.Command Specification

LOG SENSE

6.6.7.Tape Log Page (30h) (Sony Unique)

This page is a Sony unique page which provides information on the tape currently being used. This log cannot be cleared and has the following format:

Table 6-22: Tape Log Page

Bit

7

6

5

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

0

Reserved

 

Page Code (30h)

 

 

1

 

 

 

Reserved

 

 

 

 

 

2

(MSB)

 

 

Page Length

 

 

 

 

3

 

 

 

 

 

 

 

 

 

(LSB)

4

(MSB)

 

 

Parameter Code

 

 

5

 

 

 

 

 

 

 

 

 

 

6

DU (0)

DS (1)

TSD (0)

ETC (0)

 

 

TMC (00)

LBIN (0)

LP (0)

7

 

 

 

Parameter

Length (m)

 

 

8

 

 

 

Parameter Value

 

 

3+m

 

 

 

 

 

 

 

 

 

 

This page is used to return Tape Log information to the initiator in a format which conforms to the LOG SENSE command page format.

Supported Parameter Codes in this page are listed below along with their meanings:

Table 6-23: Tape Log parameter codes

Parameter Code

Description

 

 

001h

Current Groups Written

002h

Current Rewritten Tracks

003h

Current Groups Read

004h

Current C3 ECC Count

005h

Previous Groups Written

006h

Previous Rewritten Tracks

007h

Previous Groups Read

008h

Previous C3 ECC Count

009h

Total Groups Written

00Ah

Total Rewritten Tracks

00Bh

Total Groups Read

00Ch

Total C3 ECC Count

00Dh

Load Count

Length

8

8

8

8

8

8

8

8

8

8

8

8

4

This information is contained within RAM in the Drive Controller. The log is updated as the tape is used.

The term 'current' refers to information generated during the current load of the tape; 'previous' refers to information generated during the last tape load; 'total' refers to information generated since it was first initialized including the current load.

Use: An estimate of reading and writing performance can be made by the ratios of 'Total Groups Written' to 'Rewritten Tracks' and 'Groups Read' to 'C3 ECC Count'. An indication of tape degradation can be gained by comparing these ratios for 'current', 'previous' and 'total' entries.

Any attempt to change this page using LOG SELECT will result in a CHECK CONDITION with a Sense Key of ILLEGAL REQUEST. The current cumulative values will be returned regardless of the Page Control field in the

LOG SENSE CDB.

6-24

SONY AIT-5 drive SDX-1100V series Ver.1.0

Page 78