Sony SDX-1100V/R manual Safety, Conditions of Acceptability

Models: SDX-1100V/R SDX-1100V

1 192
Download 192 pages 24.1 Kb
Page 21
Image 21

2.Specification

2.4.Safety

The SDX-1100V conforms to the following safety standards:

UL/cUL

UL60950

CE (LVD)

EN60950-1

CE (EMC)

EN55024 + EN55022: Class B

C-Tick (EMC)

EN55022: Class B

 

AS/NZS CISPR22: Class B

MIC

CISPR22 + CISPR24

RPC/DoC

CISPR22

 

IEC60950-1

CB report

IEC60950-1

2.4.1.Conditions of Acceptability

The SDX-1100V is for use only in equipment where the suitability of the combination has been determined by an appropriate certification organization (for example, Underwriters Laboratories, Inc. or the Canadian Standards Association in North America, and the British Standards Institution or Verband Deutscher Elektrotechniker in Europe). Other considerations include the following:

1.An enclosure must be supplied to limit the operator’s access to live parts, to provide system stability, and to furnish the drive with the necessary grounding integrity.

2.The necessary voltage supplies must be provided. These supplies are Extra Low Voltage SEC for UL and CSA, or Safety Extra Low Voltage for BSI, VDE, and so on, of +5V and +12V DC.

2.5.Installation Requirements

Note: Do not move the drive while it is operating. It may cause malfunction.

2.5.1.Power Requirements

Voltage

Max Ripple

 

Current

 

 

 

Typical

 

Maximum

 

 

 

 

 

2.5A

5V

± 5%

100 mV p-p

1.7A

 

12V

± 10%

150 mV p-p

0.87A

 

3.0A

* exclude SCSI terminator power

4.75V

0V

5V

T

12V

0V

10.8V

-300 ms < T < 300 ms

Figure 2-5: Power-up Sequence

Note: Voltage has to increase constantly during Power-up until Maximum is reached. Do not turn off the drive while the tape is in the drive.

SONY AIT-5 drive SDX-1100V series Ver.1.0

2-9

Page 21
Image 21
Sony SDX-1100V/R manual Safety, Conditions of Acceptability, Installation Requirements Power Requirements