6.Command Specification

WRITE ATTRIBUTE

6.30.WRITE ATTRIBUTE 8Dh

The WRITE ATTRIBUTE command (Table 6-102) allows an application client to write attributes to medium auxiliary memory. Application clients will issue the READ ATTRIBUTE command prior to using this command to discover device server support for medium auxiliary memory.

Table 6-102: WRITE ATTRIBUTE command

Bit

7

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

OPERATION CODE ( 8Dh)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved for SMC –2 devices (0)

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

VOLUME NUMBER (0)

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

PARTITION NUMBER (0)

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETER LIST LENGTH

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLUME NUMBER: The VOLUME NUMBER specifies a volume within the Medium Auxiliary Memory. The number of volumes of the MAM will equal that of the attached multi-volume medium. The mult-volume is not supported by the drive. If this field is set to non-ZERO, a check condition status is returned with a ILLEGAL REQUEST sense key.

PARTITION NUMBER: The PARTITION NUMBER specifies a partition within a volume. The number of partitions of the MAM will equal that of the attached multi-partition medium. The multi partition is not supported by the drive. If this field is set to non-ZERO, a check condition status is returned with a ILLEGAL REQUEST sense key.

If the combination of VOLUME NUMBER and PARTITION NUMBER is not valid, the command will be terminated with a CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST, and the additional sense data will be set to INVALID FIELD IN CDB.

PARAMETER LIST LENGTH: The PARAMETER LIST LENGTH field specifies the length in bytes of the parameter list contained in the DATA-OUT Buffer. A parameter list length of zero indicates that no parameter data is present; this will not be considered an error. If the parameter list length results in the truncation of an attribute, the WRITE ATTRIBUTE command will be terminated with a CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST and the ASC will be set to PARAMETER LIST LENGTH ERROR.