LOG SENSE

6.Command Specification

6.6.13.MIC Fixed Length Information Page (3Dh) (Sony Unique)

Table 6-36: MIC Fixed Length Information Page

 

Bit

7

6

 

5

4

 

3

2

1

0

 

Byte

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Page Code (3Dh)

 

 

 

 

1

 

 

 

 

Reserved

 

 

 

 

 

2

(MSB)

 

 

 

Page Length (n+1)

 

 

 

 

3

 

 

 

 

 

 

 

 

 

(LSB)

 

Parameter

Code:

 

 

 

 

 

 

 

 

 

 

Code

 

 

 

 

Description

 

 

 

Length

 

0001h

MIC Logical Format Type

 

 

 

 

 

 

4

 

0002h

Device Configuration bits

 

 

 

 

 

 

4

 

0003h

Available free byte count

 

 

 

 

 

 

4

 

0004h

User Volume Note size

 

 

 

 

 

 

4

 

0005h

Reserved

 

 

 

 

 

 

 

 

8

 

0006h

Cassette

Serial Number, etc.

 

 

 

 

 

32

 

0007h

Reserved

 

 

 

 

 

 

 

 

32

 

0008h

Reserved

 

 

 

 

 

 

 

 

32

 

0009h

Reserved

 

 

 

 

 

 

 

 

32

 

000Ah

Reserved

 

 

 

 

 

 

 

 

32

 

000Bh

Reserved

 

 

 

 

 

 

 

 

32

 

000Ch

Reserved

 

 

 

 

 

 

 

 

32

 

000Dh

Reserved

 

 

 

 

 

 

 

 

32

 

000Eh

Reserved

 

 

 

 

 

 

 

 

32

 

000Fh

Reserved

 

 

 

 

 

 

 

 

32

 

0010h

Reserved

 

 

 

 

 

 

 

 

32

 

0011h

Reserved

 

 

 

 

 

 

 

 

32

 

0012h

Reserved

 

 

 

 

 

 

 

 

32

 

0013h

Reserved

 

 

 

 

 

 

 

 

32

 

0014h

Obsolete

 

 

 

 

 

 

 

 

32

 

0015h

Accumulative System Log

 

 

 

 

 

 

90

 

0016h

Volume Information

 

 

 

 

 

 

96

 

0017h

Element Address

 

 

 

 

 

 

96

 

0018h

User Partition Note size for Partition #0

 

 

 

4

Note:

1.Parameter Code 0002h AIT Device Configuration Byte is the same byte value returned in Mode Sense Page 31h byte 2. See page 6-58 paragraph 6.8.1 for a description of the fields in this byte.

2.Parameter Code 0003h Available Free Byte Count represents the current user MIC memory that is available for writing data to the MIC using the Log Select command through Page 3Eh Parameter Code 0001h, 0002h, …. 000Nh. If Available Free Byte Count is 1 or higher the application may use exactly that size or smaller to write MIC User data. If this field is ZERO a Check Condition status is returned if attempts are made to write data to the MIC. If the application attempts to write data to the MIC that is larger than this field a Check Condition status will also be returned. In both cases where Check Condition status is returned no data is written to the MIC.

SONY AIT-5 drive SDX-1100V series Ver.1.0

6-33

Page 87
Image 87
Sony SDX-1100V/R manual MIC Fixed Length Information Page 3Dh Sony Unique, MIC Fixed Length Information Bit Byte