LOG SENSE

6.Command Specification

All board revision number is 8 bytes long and has a following format:

Table 6-29: All Board Revision Number Parameter Format

0Set revision

2Board revision

4Mechanism revision

6RF revision

Each Mechanism Error Event is 24 bytes long and has following format:

Table 6-30: Mechanism Error Event Format

Byte offset

Meaning

0-3

Drum revolution minutes

4-7

Error code

6.6.10.Read and Write Frame Error Counter Page (34h & 35h)

The Read and Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in the following circumstances:

At Power On

After a cassette unloading

After a user sends a request for initialization through Log Select

Table 6-31: Read and Write Frame Error Counter Page

 

Bit

7

 

6

5

4

 

3

 

2

1

 

 

0

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Page Code (34h Write Frame Error Counters, 35h Read Frame Error Counters)

 

 

1

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

2

(MSB)

 

 

 

Page Length (88h)

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

Error Counter Descriptors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

7

 

6

5

4

 

3

 

2

1

 

 

0

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

(MSB)

 

 

 

Parameter

Code

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

 

2

DU (0)

 

DS (1)

TSD (0)

ETC (0)

 

 

TMC (0)

LBIN (0)

 

LP (0)

 

3

 

 

 

 

Parameter

Length (4)

 

 

 

 

 

4

(MSB)

 

 

 

Parameter Value

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

(LSB)

Parameter Code: This identifies which parameter of data is being transferred. The following codes are supported for each Error Counter Page.

SONY AIT-5 drive SDX-1100V series Ver.1.0

6-27

Page 81
Image 81