6.Command Specification

 

 

 

 

 

 

RECEIVE DIAGNOSTIC RESULTS

 

 

 

 

Table 6-81: RECEIVE DIAGNOSTICS results data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

7

 

6

5

 

4

 

3

2

 

1

0

 

 

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Reset

 

Time

 

Reserved

 

 

 

Error Set

 

 

 

 

Error

 

Re-Sync

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0)

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

Error

Code

 

 

 

 

 

 

2

 

 

 

 

 

 

Result A

 

 

 

 

 

 

3

 

 

 

 

 

 

Result B

 

 

 

 

 

 

4

 

 

 

 

 

Test Number

 

 

 

 

 

Reset error: This bit is set when an error occurs during power-on self-test.

Time Re-Sync:This bit indicates that the time stamp saved with the error log has no relation to that of the previous entry. It is only set by the logging routine within the data buffer as an error is logged. This field is not supported.

Error set: Various set of error codes exist. The definition of the error is dependent upon when set is taken from as follows:

0 - Runtime errors

1 - Drive mechanism diagnostic errors

2 - Drive electronics diagnostic errors

Error code: Error codes for each error set are defined in the Diagnostics clause.

Result A and B: The content of these bytes depends on the test being run. See the Diagnostics clause.

Test number: This is the test number to which the message applies (if a test fails within a sequence, the individual test number will be returned).