2.Specification

2.1.2.Weight

SDX-1100V

0.8 kg, without a cassette and a front bezel.

SDX-1100V/R

1.1 kg, without a cassette and a front bezel.

2.1.3.Connectors

The SDX-1100V has a SCSI connector with a power connector and Jumpers at the positions shown in Figure 2-3. All other connectors are for use by Sony’s manufacturing and service facilities only.

Jumpers

Figure 2-3: Connector PositionsPower Connector

SCSI 68 pin Connector

2.1.3.1. SCSI Cables and Terminators

The Single-Ended SCSI configuration and Low-Voltage-differential SCSI configuration are supported by SDX-1100V, and SDX-1100V/R The hardware specification of this interface can be found in Clause 3. Physical Characteristics, of the X3T10/1142D (SCSI Parallel Interface2) standard. Only unshielded connectors are supported. Possible cable and connector sources are listed below. This does not imply that these are the only sources for SCSI accessories.

Note: When using high speed data transfer with the SDX-1100V it is recommended that total length of the SCSI data cable not exceeded 1.5m for Single Ended SCSI configuration. As for Low-Voltage-differential SCSI configuration, less than 12m is recommended.

Cable

30 AWG Ribbon

 

Hitachi UL 20848 (or equivalent)

Connector

AMP 1-786090-7 (or equivalent)

2.2.Environmental Specifications

The specifications which apply when media is present may be different than these.

2.2.1.Temperature and Humidity Range

Temperature

Operating

5 ºC to 40 ºC (ΔT < 10 ºC/h)

Non-Operating(mech.)

-40 ºC to 70 ºC (ΔT < 20 ºC/h)

Non-Operating(tape)

-40 ºC to 45 ºC (ΔT < 20 ºC/h)

Humidity

.

Operating

20 to 80% RH, non-condensing

 

Maximum wet bulb temperature = 26 ºC

Non-operating (mech.)

5 to 95%RH(ΔRH<30%/h)

 

Maximum wet bulb temperature = 45 ºC

Non-operating (tape)

20 to 80%RH(ΔRH<30%/h)

2-4

SONY AIT-5 drive SDX-1100V series Ver. 1.0

Page 16
Image 16