2.Specification
2.2.2.Altitude
Operating
0 to 10,000 feet
2.2.3.Suspended Particulate
Operating
Less than 150 microgram/m3 Based Sampling period 24 hours
2.2.4.Vibration
Operating | Swept Sine 5 to 500Hz, @0.25G Peak 1 Octave/min. |
| 3 axis, 3 directions |
Swept Sine 5 to 500Hz, @ 0.5G Peak 1 Octave/min. | |
| 3 axis, 3 directions |
2.2.5.Shock
Operating | No Data Loss |
| Half Sine |
| Performance |
| 5 G Peak 3 ms |
| 3 axes, 3 directions |
| *Interval 10 seconds |
No Device Damage | |
| Half Sine |
| 90 G Peak 3 ms |
| (30 G Peak 11 ms) |
| 3 axes, 3 directions |
| *Interval 10 seconds |
2.2.6.Acoustic Noise
The ambient noise level is no greater than 25 dB (A). The
Streaming Write/Read | 35dB(A) |
Insert/Eject | 60dB(A) |
2.2.7.EMC
EMI/EMS | Radiated Emissions / | EN 55022 / 94 + EN 55022 A1 / 95 class B |
| Conducted noise |
|
| Emissions |
|
EMS | ESD | Discharge Voltage |
| (Front Panel Only, | Less than 15kV: No operation failure |
| integrated product) | Less than 20kV: No drive damage |
2.2.8.Orientation
The
SONY |