READ ATTRIBUTE

6.Command Specification

6.13.READ ATTRIBUTE 8Ch

The READ ATTRIBUTE command allows an application client to read attribute values from the Medium Auxiliary memory (MAM).

Table 6-65: READ ATTRIBUTE command

Bit

7

6

5

4

 

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

Operation Code (8Ch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Reserved

 

 

 

 

 

Service Action

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

Volume Number(0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

Partition Number(0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

(MSB)

 

 

First Attribute ID

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

Allocation Length

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the medium auxiliary memory is not accessible because there is no medium present, the READ ATTRIBUTE command will be terminated with a CHECK CONDITION status. The sense key will be set to NOT READY and the additional sense code will be set to MEDIUM NOT PRESENT.

If although medium is present, the Medium Auxiliary Memory is not accessible, the READ ATTRIBUTE command will be terminated with a CHECK CONDITION status. The sense key will be set to MEDIUM ERROR and the additional sense code will be set to AUXILIARY MEMORY NOT ACCESSIBLE.

The service actions defined for the READ ATTRIBUTE command are shown in Table 6-66.

SONY AIT-5 drive SDX-1100V series Ver.1.0

6-65

Page 119
Image 119
Sony SDX-1100V/R manual Read Attribute 8Ch, Read Attribute command Bit Byte Operation Code 8Ch, First Attribute ID