Spectrum Brands MC.31XX Dynamic Parameters, Order information, IntroductionHardware information

Models: MC.31XX

1 102
Download 102 pages 5.49 Kb
Page 13
Image 13

IntroductionHardware information

Dynamic Parameters

 

MC.3110

MC.3112

MC.3120

MC.3122

MC.3130

MC.3132

 

MC.3111

 

 

MC.3121

 

 

MC.3131

 

 

Test - Samplerate

1

MS/s

1

MS/s

10 MS/s

10 MS/s

25 MS/s

25 MS/s

Testsignal frequency

90 kHz

90 kHz

1

MHz

1

MHz

1

MHz

1

MHz

SNR (typ)

> 67.5 dB

> 66.9 dB

> 64.9 dB

> 64.9 dB

> 63.1 dB

> 62.4 dB

THD (typ)

< -62.8 dB

< -62.8 dB

< -62.5 dB

< -62.5 dB

< -62.5 dB

< -62.5 dB

SFDR (typ), excl harm.

> 80.8 dB

> 80.5 dB

> 80.5 dB

> 78.5 dB

> 79.5 dB

> 79.3 dB

SINAD (typ)

> 61.5 dB

> 61.4 dB

> 60.5 dB

> 60.5 dB

> 59.8 dB

> 59.4 dB

ENOB (based on SINAD)

> 9.9 LSB

> 9.9 LSB

> 9.8 LSB

> 9.8 LSB

> 9.6 LSB

> 9.6 LSB

Dynamic parameters are measured at ± 1 V input range (if no other range is stated) and 50 Ohm termination with the samplerate specified in the table. Measured parameters are aver- aged 20 times to get typical values. Test signal is a pure sine wave of the specified frequency with > 99% amplitude. SNR and RMS noise parameters may differ depending on the quality of the used PC. SNR = Signal to Noise Ratio, THD = Total Harmonic Distortion, SFDR = Spurious Free Dynamic Range, SINAD = Signal Noise and Distortion, ENOB = Effective Number of Bits. For a detailed description please see application note 002.

Order information

Order No

Description

 

Order No

Description

MC3110

MC.3110 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-16M

Option: 16 MSample memory instead of 8 MSample standard mem

MC3111

MC.3111 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-32M

Option: 32 MSample memory instead of 8 MSample standard mem

MC3112

MC.3112 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-64M

Option: 64 MSample memory instead of 8 MSample standard mem

MC3120

MC.3120 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-128M

Option: 128 MSample memory instead of 8 MSample standard mem

MC3121

MC.3121 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-256M

Option: 256 MSample memory instead of 8 MSample standard mem

MC3122

MC.3122 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-up

Additional handling costs for later memory upgrade

MC3130

MC.3130 with 8 MSample memory and drivers/SBench 5.x

 

 

 

MC3131

MC.3131 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-mr

Option Multiple Recording: Memory segmentation

MC3132

MC.3132 with 8 MSample memory and drivers/SBench 5.x

 

MC3xxx-gs

Option Gated Sampling: Gate signal controls acquisition

 

 

 

MC3xxx-dig

Additional 4 synchronous digital inputs per channel, incl. cable

MC3xxx-smod

Star Hub: Synchronisation of 2 - 16 boards, one option per system

 

 

 

MC3xxx-time

Timestamp option: Extra memory for trigger time

 

MC31xx-dl

DASYLab driver for MC.31xx series

MCxxxx-xmf

Extra I/O, external connector: 24 DI/O, 4 Analog out, incl. cable

 

MC31xx-hp

VEE driver for MC.31xx series

 

 

 

MC31xx-lv

LabVIEW driver for MC.31xx series

MC3xxx-cs

Synchronisation of 2 - 4 boards, one option per system

 

MATLAB

MATLAB driver for all MI.xxxx, MC.xxxx and MX.xxxx series.

Cab-3f-9m-80

Adapter cable: SMB female to BNC male 80 cm

 

Cab-3f-9f-80

Adapter cable: SMB female to BNC female 80 cm

Cab-3f-9m-200

Adapter cable: SMB female to BNC male 200 cm

 

Cab-3f-9f-200

Adapter cable: SMB female to BNC female 200 cm

 

 

 

 

 

(c) Spectrum GmbH