ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

UIM

The UIM (User Interface Module) is the display on the front of the water heater. The UIM’s major components include a Circuit Board with LCD display and a Button Pad Overlay which contains the five user input buttons.

Service Notes - Button Pad Ribbon Cable

The Ribbon Cable that connects the Button Pad Overlay to the UIM Circuit Board must be plugged in exactly as shown in the images below; with the metal crimp connections visible on the plug end and the UIM Circuit Board back facing out. There are six pins on this Ribbon cable socket, Ensure all six pins are inserted into the Ribbon Cable plug whenever removing or installing the UIM or Button Pad Overlay.

Failure to connect this Ribbon cable exactly as shown when servicing will render the User Input Buttons inoperable. This should be checked whenever the nature of the service complaint is an inoperable or unresponsive controller or UIM.

Button Pad Overlay

Ensure Ribbon Cable Plug is inserted exactly as shown.

UIM Circuit Board Back

J2 Socket - CCB

J3 Socket - Button Pad

Communication

Communication

Ribbon Cable To

Button Pad

 

LCD

UIM Circuit Board Front

Screen

 

Technical Literature Department

27 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 28
Image 28
State Industries SHE50-100NE, SHE50-100PE, GP650HTPDT manual Uim, Service Notes Button Pad Ribbon Cable