ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

CONTROL SYSTEM MENUS (CONT)

Heater Information: This menu contains historic operational and configuration information. Information/settings available:

Elapsed Time - hrs & mins - how long the water heater has been powered on

Burner On Time - hrs & mins - burner run time cumulative

Cycle Count - total number of heating cycles

Ignition Failure Count - total number of ignition failures

Flame Loss Count - total number of lost flame events

CCB Version - software revision of the control systems CCB circuit board

UIM Version -software revision of the control systems UIM circuit board

Configuration - manufacturer and model number configuration

Current Fault: This menu will only contain information when the water heater is in a lock out condition. It will contain the current fault message/condition.

Fault History: This menu contains a history of fault occurrences with a time stamp. The time stamp associated with the fault condition can be subtracted from the “Elapsed Time” in the “Heater Information” menu to determine when or how long ago the given event occurred. The control system will keep the last 9 events in history. When a new event occurs the oldest event will be lost.

Fault Occurrence: This menu contains a running total (cumulative) for all fault conditions declared by the control system. This information can be useful in determining root causes for service problems. Information/settings available:

Ignition Failure

ECO

Blocked Inlet

Blocked Outlet

Thermostat Input 4

Blower Prover

Flame Detect Error

Flame Probe

External Output Relay

Gas Valve

Igniter Fail

Power Supply Fail

CCB Hardware

Model Faults

CCB Communications

Restore Factory Defaults: This menu allows the end user to restore all settings to their factory defaults.

Help Menu: This menu contains information to help users use the control system, menu items include; Operating Instructions, Status Icon Legend, Operating States, Adjust Operating Set Point, Change Display Units, Restore Factory Defaults, Contact Information.

Technical Literature Department

34 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 35
Image 35