ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

FAULT MESSAGES (CONT)

DISPLAYED MESSAGE

CHECK/REPAIR

CONDITION/INDICATES

 

 

 

“Upper Probe Short”

• Check all wiring between the Temperature

 

Probe and the J7 Socket on the CCB (page 36).

The control system has detected less than 390

Repair/replace anything worn or damaged.

 

ohms from the Temperature Probe on top of the

• Unplug J7 plug from CCB, check resistance

water heater.

between the two black wires in the plug end with

 

an ohm meter. If resistance is at or below 390

 

ohms - replace the Temperature Probe.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

“Flame Probe Short”

• Disconnect the wire from the flame sensor (see

 

pages 12 and 24). Check for continuity between

The control system has detected that the flame

flame sensor and ground with an ohm meter.

There should be no continuity - infinite resis-

sensor is grounded.

tance.

 

 

• If above test indicates there is continuity

 

between the flame sensor and ground - remove

 

the flame sensor (see pages 12 and 24). Ensure

 

the flame sensor is not bent and touching the

 

burner.

 

• Check all flame sensor wiring between the

 

flame sensor and the J4 male spade connector

 

on the CCB (page 36). Ensure there are not any

 

pinched wires or shorts - repair/replace anything

 

worn or damaged.

 

• Replace the flame sensor.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.