State Industries GP650HTPDT manual “Low Igniter Current”, Fault Messages Cont, Displayed Message

Models: GP650HTPDT SHE50-100NE SHE50-100PE

1 54
Download 54 pages 60.84 Kb
Page 50
Image 50
“Low Igniter Current”

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

FAULT MESSAGES (CONT)

DISPLAYED MESSAGE

CHECK/REPAIR

CONDITION/INDICATES

 

 

 

“Low Igniter Current”

• Check all wiring between CCB’s J5 Socket

 

(page 35) pins 1 & 2 and the hot surface igniter.

The control system has detected less than 2.0 AC

Repair/replace anything worn or damaged as

necessary.

amps through the igniter during the igniter warm up

 

period.

• Perform close visual inspection of the pins

 

inside the CCB J5 plug and socket - ensure

 

plugs and sockets are mating properly and pro-

 

viding good contact. Repair/replace anything

 

worn or damaged as necessary.

 

• With power turned on and a call for heat active -

 

ensure there is 120 VAC between pins 1 & 2 of

 

the CCB’s J5 Socket during the igniter warm up

 

period. - the igniter lighting bolt icon will appear

 

on the UIM display during the igniter warm up

 

period. See Table 4 on page 30.

 

• Turn off power to the water heater - disconnect

 

wires to igniter at the igniter. Check for continu-

 

ity between the two igniter wires. If the igniter

 

shows to be an open circuit - replace the igniter.

 

• With power turned on and a call for heat active -

 

check amp draw through the igniter with an AC

 

amp meter during the igniter warm up period.

 

This procedure is illustrated and explained on

 

page 25. Replace igniter if amp draw is less

 

than 3.0 AC amps.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 