OPERATING SET POINT ADJUSTMENT

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

OPERATING SET POINT ADJUSTMENT

When the temperature sensed by the control system at the Temperature Probe (top of the water heater) reaches the Operating Set Point the control system will end the heating cycle. A call for heat will be activated again when the tank temperature drops below the Operating Set Point minus the Differential setting plus one degree.

Example: Operating Set Point is 120°, Differential setting is 2° (factory default). A call for heat will be activated when tank temperature drops to 117°. 120 - (2+1) = 117.

The Operating Set Point and the Differential setting is adjusted or changed in the Temperatures menu. The following illustrations and instructions will explain how to adjust these user settings and navigate the control system menus.

ACTION

DISPLAY

From the desktop screen, press MENU.

NOTE: Notice how the text on the UIM display above the Operational Buttons changes as you navigate through the various menus and screens.

With Temperatures selected (highlighted in black) in the Main Menu, press the Operational Button underneath “SELECT” to enter the Temperatures Menu.

If Temperatures is not selected use the Up and Down buttons to select this menu item.

With the Operating Set Point selected in the Temperatures Menu, press the Operational Button underneath “CHANGE” to activate the adjustment mode for this menu item.

NOTE: The Upper Probe Offset can be used to override the control system’s calculated tank temperature by 5° above or below current reading. Adjustable range is -5°F to +5°F.

Press the UP and DOWN buttons to adjust the Operating Set Point to the desired setting.

Press the Operational Button underneath “UPDATE” to confirm the new setting or “CANCEL” to discard the new setting and retain the previous setting.

NOTE: This same procedure can also be used to adjust the Differential and the Upper Probe Offset user settings.

Technical Literature Department

32 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 