ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

VENTURI

A Venturi is connected to the inlet of the blower. All combustion air flows through the Venturi. The outlet of the 24 VAC gas valve connects directly to the side of the Venturi. Fuel gas flows from the outlet of the gas valve into the side of the Venturi directly.

Inside the Venturi there is a cone shaped restrictor that constricts the air passage to the blower inlet. As air enters the constriction point it’s velocity increases. A pressure drop occurs at this point and creates a negative pressure in the cavity between the cone shaped restrictor and the Venturi housing. This negative pressure “pulls” gas from the outlet of the gas valve into the blower where it is mixed with combustion air and then supplied to the burner. See the images below.

Blower

24 VAC Gas Valve

Gas Inlet

Venturi Inlet

Venturi

Negative Pressure

Blower

Velocity Increases

Combustion Air At Constriction Point

Pressure Drops

Negative Pressure

GAS VALVE

Burner

 

Supply Gas

Technical Literature Department

14 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 15
Image 15
State Industries SHE50-100PE, SHE50-100NE, GP650HTPDT manual Venturi, Blower