State Industries GP650HTPDT “Blocked Inlet”, Fault Messages Cont, Displayed Message, Check/Repair

Models: GP650HTPDT SHE50-100NE SHE50-100PE

1 54
Download 54 pages 60.84 Kb
Page 47
Image 47
“Blocked Inlet”

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

FAULT MESSAGES (CONT)

DISPLAYED MESSAGE

CHECK/REPAIR

CONDITION/INDICATES

 

 

 

“Blocked Inlet”

• If the water heater has been installed as a con-

 

ventional vent appliance - Ensure the intake air

The control system has detected open contacts at

connection screen is not clogged with debris.

See Service Notes - Venting on page 7.

the Blocked Intake air pressure switch - inadequate

 

supply of intake (combustion) air.

• If water heater has been installed as a direct

 

vent appliance - check for restrictions, too many

 

equivalent feet, or too many elbows in the intake

 

air piping. Review venting installation section of

 

the Instruction Manual that came with the water

 

heater - see Table 1 on page 7 in this manual.

 

Ensure the vent/intake air piping has been

 

installed within manufacturers requirements.

 

• If water heater has been installed as a direct

 

vent appliance - temporarily disconnect the

 

intake air pipe at the blower connection on the

 

water heater - ensure the screen inside the

 

intake air connection was removed during

 

installation. See the Service Notes for venting

 

on page 7.

 

• Check all wiring between the Blocked Intake air

 

pressure switch and the CCB’s J6 Socket (page

 

36) pins 4 & 14. Perform close visual inspection

 

of the pins inside the plug and socket - ensure

 

plugs and sockets are mating properly and pro-

 

viding good contact. Repair/replace anything

 

worn or damaged.

 

• Review the air pressure switch information

 

beginning on page 18. Perform the pressure

 

switch test procedure for the Blocked Intake air

 

pressure switch - see pages 21 through 23.

 

Replace the Blocked Intake switch if defective.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 

Technical Literature Department

46 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 47