State Industries GP650HTPDT Fault Messages, “AC Reversed”, “Upper Probe Open”, Displayed Message

Models: GP650HTPDT SHE50-100NE SHE50-100PE

1 54
Download 54 pages 60.84 Kb
Page 44
Image 44
FAULT MESSAGES

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

FAULT MESSAGES

DISPLAYED MESSAGE

CHECK/REPAIR

CONDITION/INDICATES

 

 

 

“AC Reversed”

• Check incoming power supply wiring to the

 

water heater in the junction box - ensure that

The control system has detected the power supply

the hot wire is connected to the water heater’s

black wire and the neutral wire is connected to

polarity is reversed.

the water heater’s white wire inside the junction

 

 

box. See electrical requirements on page 8.

 

• Check for 120 VAC at CCB’s J3 Socket (page

 

36) pins 1 & 3 with J3 plug inserted, power on.

 

Check for AC voltage between pin 1 and ground

 

- should indicate 120 VAC.

 

Check for AC voltage between pin 3 and ground

 

- should indicate 0 VAC.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 

“Upper Probe Open”

• Check Temperature Probe plug and socket con-

 

nection at CCB’s J7 Socket (page 36). Perform

The control system has detected over 56,000 ohms

close visual inspection of the pins inside the

plug and socket - ensure plugs and sockets are

from the Temperature Probe on top of the water

mating properly and providing good contact.

heater.

• Check all wiring between the Temperature

 

 

Probe and the J7 Socket on the CCB. Repair/

 

replace anything worn or damaged.

 

• Unplug J7 plug from CCB, check resistance

 

between the two black wires in the plug end with

 

an ohm meter. If resistance is above 56,000

 

ohms - replace the Temperature Probe.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 

Technical Literature Department

43 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 44