State Industries SHE50-100PE Spare, Vent, J9 Port - Communication Port - Not Used, Retry, Use Yes

Models: GP650HTPDT SHE50-100NE SHE50-100PE

1 54
Download 54 pages 60.84 Kb
Page 39
Image 39
J9 Port - Communication Port - Not Used

ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

CCB (CONT)

J7 Socket - Temperature Probe/ECO (immersion probe - top of the water heater)

PIN #

DESCRIPTION

1ECO (energy cut out) 24 VAC out (red wire)

2Upper temperature probe (thermistor) +5.0 VDC (black wire)

3Upper temperature probe (thermistor) -5.0 VDC (black wire)

4ECO (energy cut out) 24 VAC return (red wire)

J9 Port - Communication Port - Not Used

 

J10

Socket - Not Used

 

J11 Port - Communication Port - Not Used

 

J13

Socket - Blower Speed Control (VFD)

 

 

 

 

 

 

 

PIN #

DESCRIPTION

1Not used

2Not used

3To Blower low voltage PWM plug (see page 10) - pin #5 (white w/grn stripe)

4Not used

5Not used

6Not used

7To Blower low voltage PWM plug (see page 10) - pin #4 (white w/blue stripe)

8To Blower low voltage PWM plug (see page 10) - pin #1 (white w/brn stripe)

J15 Socket - Not Used

J16 Port - Communication Port - UIM Display (user interface module) S1 Dip Switch

The S1 dip switches are configured from the factory and should not be changed. The illustration below shows the 4 dip switches with labeling. Dip switches are toggle type micro switches. Flipping a dip switch towards “Open” would be the same as “Off.” Flipping a dip switch the other way (towards the switch numbers) is the same as “On.”

Dip switch #1 is used to configure the water heater to declare a fault condition and lock out after one or three failed trials for ignition. The factory setting is “on” for three trials.

Dip switches #2 and #3 are used when this control system is installed on other products. The factory setting for these two dip switches is “on.”

Dip switch #4 is a spare, configuration does not matter.

OFF

OPEN

 

1 Retry

1

3

 

 

Retries

 

 

 

 

ON

Ext

Use Yes

2 3

No

Input Type Tstat OPEN

Vent

CLOSED

 

Spare

4

Spare

 

 

 

 

Technical Literature Department

38 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 39
Image 39
State Industries SHE50-100PE manual Spare, Vent, J9 Port - Communication Port - Not Used, Socket - Not Used, Retry, Use Yes