ULTRA HIGH EFFICIENCY POWER VENT/POWER DIRECT VENT - SERVICE MANUAL

FAULT MESSAGES (CONT)

DISPLAYED MESSAGE

CHECK/REPAIR

CONDITION/INDICATES

 

 

 

“Gas Valve Failure”

• Turn off power - check all wiring and connectors

 

between the CCB’s J6 Socket (page 35) pins 2

The control system has not detected any current

& 15 and the Gas Valve’s solenoid coil. Repair/

replace anything worn or damaged as neces-

through the gas valve after it has been energized.

sary.

 

 

• Perform close visual inspection of the pins

 

inside the CCB J6 plug and socket - ensure

 

plugs and sockets are mating properly and pro-

 

viding good contact. Repair/replace anything

 

worn or damaged as necessary.

 

• Turn off power - disconnect the Gas Valve wir-

 

ing plug on top of the Gas Valve solenoid coil.

 

Check Gas Valve solenoid coil resistance with

 

an ohm meter at the solenoid coil terminals.

 

Normal resistance is approximately 7 million

 

ohms. If the Gas Valve solenoid coil is an open

 

circuit - replace the Gas Valve.

 

• Check for 24 VAC at CCB’s J6 Socket pins 2 &

 

15 during the Ignition Activation operating state

 

(the Gas Valve status icon will be visible on the

 

UIM display during this period.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 

“Communication Failure”

• Turn off power - check the communication cable

 

connections between the J2 Socket on the UIM

Loss of communication between the CCB and the

circuit board (page 27) and the CCB J16 Port

(page 35).

UIM.

• Try a new communication cable (standard cate-

 

 

gory V network cable) between the CCB and the

 

UIM.

 

• Call the technical support phone number shown

 

on the water heater labeling for further assis-

 

tance if the problem has not been corrected

 

after performing the procedures outlined here.

 

 

Technical Literature Department

52 of 52

Ashland City, TN © 2008

Servicing should only be performed by a Qualified Service Agent

 

Page 53
Image 53
State Industries GP650HTPDT, SHE50-100PE, SHE50-100NE manual Gas Valve Failure, Communication Failure