Using the Alarm System

Owner’s Manual - Regal Intensive Care Unit

The alarm system alerts you, with audible and visual signals, when- ever there is a problem with the oxygen supply or concentration.

Turning the alarm system on

1.Make sure the main on/off switch is On. The amber light in the switch should be On (refer to Page 48).

2.Make sure the oxygen on/off switch is On. The amber light in the switch should be On (refer to Page 51). Note: The alarm system only operates when the oxygen system is On.

3.Push the alarm on/off switch to On. The amber light in the switch comes on (Figure 58). The alarm system is now in the operating mode.

Turning the alarm system off

Push the alarm on/off switch to Off. The light in the switch goes out.

Recognizing an alarm

When an alarm occurs, the audible alarm sounds and the red alarm system light comes on.

Responding to an alarm

System On/Off

Light Switch

Figure 58. Alarm Controls

1.Push the five system on/off switches to Off , starting at the oxygen on/off switch and proceeding down (heat, cooling, alarm, left floor heat, right floor heat). The lights in all the switches, and all system lights go out.

2.Push the main on/off switch to Off. The light in the switch goes out (refer to Page 48).

3.Locate and fix the problem.

4.Re-start the unit and continue normal operating procedures.