Chapter 4 - Operation and Care

If the oxygen system experiences a minor, transient fault and then corrects itself, the alarm may sound briefly and then stop. In this case, it is not necessary to shut down the unit and you may continue normal operations. If this happens frequently, however, check the oxygen system and try to locate and correct the problem.

The alarm system includes a time delay to minimize alarms due to minor, transient faults. For more information, refer to Setting the Time Delay Relay on Page 59.

Controlling Oxygen There is no oxygen pressure adjustment in the Intensive Care Unit. Pressure To increase or decrease oxygen pressure to the Intensive Care Unit,

adjust the regulator at the oxygen supply source.

Controlling Oxygen The oxygen flow rate is controlled by a flow rate meter and adjust- Flow Rate ment knob (Figure 59) on the front of the electronics compartment.

The meter is calibrated from 1/2 to 15 lpm (liters-per-minute).

SSCI recommends an intake pressure of 10 to

20 psi with a flow rate of 15 lpm. Your experience may indicate that a greater or lower pressure and/ or flow rate are desirable.

To increase the flow rate, turn the adjustment knob clockwise. To reduce the flow rate, turn the knob counter-clockwise. Take your readings from the center of the ball in the transparent, graduated tube on top the meter.

Adjustment

Knob

Figure 59. Oxygen Flow Meter and

Adjustment Knob

56

SSCI - Suburban Surgical Company, Inc.

Page 68
Image 68
Suburban Mfg 12019-01-NGFREP manual Oxygen Flow Meter Adjustment Knob

12019-01-NGFREP specifications

Suburban Mfg 12019-01-NGFREP is a well-regarded water heater that stands out in the market for its reliability and efficiency. Designed with the modern consumer in mind, it caters effectively to both residential and light commercial applications. This water heater is particularly recognized for its robust construction, versatile installation options, and advanced technological features.

One of the key attributes of the Suburban Mfg 12019-01-NGFREP is its high-efficiency operation. It is equipped with a state-of-the-art heating system that maximizes energy utilization while minimizing waste. This efficiency not only contributes to cost savings in utility bills but also supports environmentally friendly practices by reducing carbon footprints. The water heater operates with a powerful 6-gallon capacity tank, ensuring that households have a steady and ample supply of hot water.

Another main feature contributing to its popularity is the dual-fuel technology. This model can operate on both electric and gas power sources, providing flexibility to users in selecting their preferred energy type. This attribute is especially beneficial in areas prone to power outages or where energy prices fluctuate.

The design of the Suburban 12019-01-NGFREP also reflects user convenience. It is compact and lightweight, which simplifies the installation process, allowing it to fit into tight spaces, making it an ideal solution for mobile homes, RVs, or smaller residential units. The unit is also built with durable materials, protecting it against corrosion and wear over time, thus enhancing its longevity and performance.

Another significant aspect of the Suburban Mfg water heater is its safety features. It comes equipped with an automatic shut-off valve that activates in case of overheating, ensuring protection for both the unit and the occupants. Additionally, it incorporates pressure relief mechanisms to further enhance safety, making it a dependable choice for consumers.

Moreover, the unit’s ease of maintenance is a valued characteristic. It provides accessible design elements that simplify routine checks and repairs, saving users time and effort when servicing the water heater.

In summary, Suburban Mfg 12019-01-NGFREP is a versatile, efficient, and reliable water heater that is tailored to meet modern demands. Its combination of dual-fuel operation, high energy efficiency, compact design, and safety features makes it a smart investment for households seeking comfort and performance in their water heating solutions.