Suburban Mfg 12019-01-NGFREP manual Thermostat Knock-out

Models: 12019-01-NGFREP

1 184
Download 184 pages 31.08 Kb
Page 128
Image 128

Chapter 5 - Repairs & Replacements

Knock-out

Wire

Terminals

Figure 132. Thermostat Knock-out

11.Mount the thermostat and bracket to the partition wall (Figure 124).

12.Neatly coil up the excess capillary tubing and bind it to the adhesive tie mount with a small wire tie (Figure 129).

13.Replace the Sodalime pan.

14.Close and secure the filter/fans compart- ment panel (Page 58).

15.Close and secure the electronics compart- ment door (Page 57).

16.Plug the power cord into its wall outlet.

Audible Alarm CAUTION: Before proceeding, make sure the unit is

P/N 853458

Off, and the electric power cord un-plugged.

 

 

 

Tool and Supplies Required

 

„

Phillips screwdriver

 

„

Markers, masking tape, tags, or other means to mark wires

 

Removal

 

1.

Make sure that the main on/off switch is Off and the

 

 

amber light in the switch is out.

 

2.

Unplug the power cord from the electrical outlet.

 

3.

Open the electronics compartment (refer to Page 57).

 

4.

Using tags, masking tape, or any other convenient means,

 

 

tag the wires with the identification of the terminal to which

 

 

they attach (Figure 123). Failure to mark the wires will

 

 

make it difficult to connect them correctly later.

 

5.

With a Phillips screwdriver, remove all wires from the rear

 

 

of the audible alarm.

 

6.

Close the electronics compartment door.