6.4REMOTE VOLTAGE PROGRAMMING OF OUTPUT VOLTAGE AND OUTPUT CURRENT

CAUTION

To maintain the power supply isolation and to prevent ground loops, use an isolated programming source when operating the power supply via remote analog programming at the J1 connector.

Perform the following procedure to set the power supply to Remote Voltage programming:

1.Turn the power supply AC On/Off switch to Off.

2.Set setup switch SW1, positions 1 and 2 to their UP position.

3.Set SW1, position 3 to select the programming voltage range according to Table 6-3.

4.Ensure that SW1, positions 7 and 8 are at their DOWN (default) position.

5.Connect a wire jumper between J1-8 and J1-12 (refer to Table 4-4).

6.Connect the programming source to the mating plug of J1 as shown in Fig.6-1. Observe correct polarity for the voltage source.

7.Set the programming sources to the desired levels and turn the power supply ON. Adjust the programming sources to change the power supply output.

NOTES:

1.SW1, positions, 4, 5, 6 and 9 are not required for remote programming. Their settings can be determined according the application.

2.The control circuits allow the user to set the Output Voltage and Output Current up to 5% over the model-rated maximum value. The power supply will operate within the extended range, however it is not recommended to operate the power supply over its voltage and current rating, and performance is not guaranteed.

Table 6-3: SW1-3 setting and programming range

SW1-3 setting

Output Voltage programming

Output Current programming

 

VPGM (J1-9)

IPGM (J1-10)

UP

0-10V

0-10V

DOWN

0-5V

0-5V

J1 connector, rear panel view

OUTPUT CURRENT

PROGRAMMING

+

 

12

10

13

 

25

 

 

23

 

OUTPUT VOLTAGE

 

PROGRAMMING

 

+

9

8

 

1

 

14

22

 

Fig.6-1: Remote voltage programming connection

46

83-507-013 Rev. D

Page 54
Image 54
TDK 1500W, 750W technical manual Down, Remote voltage programming connection