83
-
507
-
013 Rev. D
46
CAUTION
To maintain the power supply isolation and to prevent ground loops, use an
isolated programming source when operating the power supply via remote
an
a
log programming at the J1 connector.
6.4 REMOTE VOLTAGE PROGRAMMING OF OUTPUT VOLTAGE AND OUTPUT
CURRENT
Per
form the following procedure to set the power supply to Remote Voltage programming:
1.
Turn the power supply AC On/Off switch to Off.
2.
S
et setup switch SW1, positions 1 and 2 to their UP position.
3.
Set SW1, position 3 to select the programming voltage range acc
ording to Table 6
-
3.
4.
Ensure that SW1, positions 7 and 8 are at their DOWN (default) position.
5.
Connect a wire jumper between J1
-
8 and J1
-
12 (refer to Table 4
-
4).
6.
Connect the programming source to the mating plug of J1 as shown in Fig.6
-
1. Observe
correct po
larity for the voltage source.
7.
Set the programming sources to the desired levels and turn the power supply ON. Adjust
the programming sources to change the power supply output.
NOTES:
1.
SW1, positions, 4, 5, 6 and 9 are not required for remote programming.
Their settings can
be determined according the application.
2.
The control circuits allow the user to set the Output Voltage and Output Current up to 5%
over the model
-
rated maximum value. The power supply will operate within the extended
range, however it is
not recommended to operate the power supply over its voltage and
current ra
t
ing, and performance is not guaranteed.
Table 6
-
3: SW1
-
3 setting and programming range
SW1
-
3 setting
Output Voltage progra
m
ming
VPGM (J1
-
9)
Output Current progra
m
ming
IPGM (J1
-
1
0)
UP
0
-
10V
0
-
10V
DOWN
0
-
5V
0
-
5V
1
14
13
25
10
12
8
9
23
22
+
+
OUTPUTCURR ENT
PROGRAMMING
OUTPUTV OLTAGE
PROGRAMMING
J1 connector, rear panel view
Fig.6-1: Remote voltage programming connectio n