GEN750W models

GEN1500W models

Table 7-4: Current programming range

Table 7-5: Current programming range

Model

Minimum

Maximum

(A)

(A)

 

GEN6-100

000.00

100.00

GEN8-90

00.00

90.00

GEN12.5-60

00.000

60.000

GEN20-38

00.000

38.000

GEN30-25

00.000

25.000

GEN40-19

00.000

19.000

GEN60-12.5

00.000

12.500

GEN80-9.5

0.000

9.500

GEN100-7.5

0.000

7.500

GEN150-5

0.000

5.000

GEN300-2.5

0.000

2.500

GEN600-1.3

0.000

1.300

Model

Minimum

Maximum

(A)

(A)

 

GEN6-200

000.00

200.00

GEN8-180

000.00

180.00

GEN12.5-120

000.00

120.00

GEN20-76

00.00

76.00

GEN30-50

00.000

50.000

GEN40-38

00.000

38.000

GEN60-25

00.000

25.000

GEN80-19

00.000

19.000

GEN100-15

00.000

15.000

GEN150-10

00.000

10.000

GEN300-5

0.000

5.000

GEN600-2.6

0.000

2.600

NOTE:

The power supply can accept values higher 5% than the table values, however it is not recommended to program the power supply over the rated values.

Table 7-6: OVP programming range

Model

Minimum

Maximum

Rated Output Voltage (V)

(V)

(V)

 

 

6

0.5

7.50

8

0.5

10.0

12.5

1.0

15.0

20

1.0

24.0

30

2.0

36.0

40

2.0

44.0

60

5.0

66.0

80

5.0

88.0

100

5.0

110.0

150

5.0

165.0

300

5.0

330.0

600

5.0

660.0

Table 7-7: UVL programming range

Model

Minimum

Maximum

Rated Output Voltage (V)

(V)

(V)

 

 

6

0

5.70

8

0

7.60

12.5

0

11.9

20

0

19.0

30

0

28.5

40

0

38.0

60

0

57.0

80

0

76.0

100

0

95.0

150

0

142

300

0

285

600

0

570