Manuals
/
TDK
/
Computer Equipment
/
Power Supply
TDK
technical manual
Genesystm 750W & 1500W Power Supplies Outline Drawings
Models:
1500W
750W
1
20
80
80
Download
80 pages
46.83 Kb
17
18
19
20
21
22
23
24
Specifications
Supplemental Characteristics
Install
Error codes
Signal
Fault Enable Register
Sicherheits-und Warnsymbole
Connecting the Load
Warranty
Maintenance
Page 20
Image 20
2.13
GENESYS
TM
750W & 1500W POWER SUPPLIES OUTLINE DRAWINGS
12
83-507-013
Rev. D
Page 19
Page 21
Page 20
Image 20
Page 19
Page 21
Contents
Genesystm 750W/1500W
Page
Page
Genesys Manual Supplement
Table of Contents
Front and Rear Panel Controls and Connectors ………...………
Remote Analog PROGRAMMING………………………………………………
Isolated Analog Programming OPTION…………………………………
Limitation of Warranty
Warranty Service
Disclaimer
Trademark Information
Safety Instructions
Environmental Conditions
SICHERHEITS-INSTALLATIONS Anweisungen
Umweltbedingungen
Sicherheits-und Warnsymbole
Anderungen and Bauteileersatz
Features and options
General Information
Introduction
General Description
Multiple output power system
Control via the serial communication port
Analog voltage programming and monitoring
Parallel operation
Accessories
Specifications
Chapter
Vout
Supplemental Characteristics
Genesystm 750W & 1500W Power Supplies Outline Drawings
Installation
General
Preparation for USE
Initial Inspections
AC Input Power Connection
LOCATON, Mounting and Cooling
AC Source Requirements
Rack Mount Slides optional
AC Input Connector, 1500W models
AC Input Connector, 750W models
AC Input Wire Connection, 1500W models
AC Input Cord
Prior to Operation
TURN-ON Checkout Procedure
General
Constant Voltage Check
Constant Current Check
OVP Check
UVL Check
Connecting the Load
Wire termination
AWG
Making the load connections 6V to 60V Models
Noise and Impedance Effects
Inductive loads
Wire terminal lug 2 places
80V to 600V Models
Load wires connection to the output connector
Connecting multiple loads, radial distribution method
Connecting single loads, local sensing default
Connecting single loads, remote sensing
Multiple load connection with distribution terminals
Grounding outputs
Sense wiring
Output Terminal Grounding
Local and Remote Sensing
Local sensing
10.4 J2 sense connector technical information
Remote sensing
Front and Rear Panel Controls and Connectors
Front Panel Controls and Indicators
Auxiliary Function
Rear Panel Connections and Controls
Rear panel connections and controls
Rear Panel SW1 Setup Switch
Resetting the SW1 switch
1 SW1 position function
Rear Panel J1 Programming and Monitorng Connector
Making J1 connections
Signal
Enain
Ifcom
Local
Local Operation
Constant Voltage Mode
Constant Current Mode
Setting the OVP level
Resetting the OVP circuit
Over Voltage Protection OVP
Automatic Crossover
Output SHUT-OFF SO Control VIA Rear Panel J1 Connector
Under Voltage Limit UVL
Foldback Protection
Output ON/OFF Control
Psok Signal
ENABLE/DISABLE Control VIA Rear Panel J1 Connector
CV/CC Signal
Over Temperature Protecton OTP
Last Setting Memory
Auto-restart mode
Safe-start mode
Series Operation
Series connection for increased output voltage
Series connection for positive and negative output voltage
Series connection for positive/negative output voltages
Parallel Operation
Advanced parallel configuration
Setting the units as Master or Slave
Master and Slave units default operation
Connection to the load
AST OFF *OUT OFF
To release units from Slave mode
Current display accuracy
DAISY-CHAIN Connection
Front Panel Locking
Unlocked front panel
Locked front panel
Remote Analog Programming
LOCAL/REMOTE Analog Indication
Down
Remote voltage programming connection
Resisitive Programming of Output Voltage and Current Limit
Remote resistive programming
Remote Monitoring of Output Voltage and Current
RS232 & RS485 Remote Control
Configuration
Front panel in Remote mode
Rear Panel RS232/RS485 Connector
6 RS232/RS485 port in Local mode
MD Mode Option Factory Installed MD Mode Description
MD Mode enable Serial communication mode
MD Mode SRQ
MD Mode SRQ Retransmission
Connecting Power Supplies to RS232 or RS485 BUS
Single power supply
Communication Interface Protocol
Error Messages
Command SET Description
Output Control Commands
Initialization Control Commands
ID Control Commands
DVC?
Filter
FILTER?
OUT?
Global Output Commands
Single Byte Commands
Enable MD Mode MD Mode Option Required
Disable SRQ retransmission MD Mode Option Required
Enable SRQ retransmission MD Mode Option Required
Addressed commands with response Read registers
Print Power On Time
Test if MD Mode is Installed
Addressed commands without response Acknowledge SRQ
1010 None Disable retransmission of SRQs by
GEN750W models GEN1500W models Current programming range
STATUS, Error and SRQ Registers
10.6 Status Control Commands
Conditional Registers
Status Registers
Service Request Enable and Event Registers
BIT
Fault Enable Register
Fault Event Register
Status Enable Register
Status Event Register
Communication Test
Power supply set-up
Serial Communication Test SET-UP
Specifications
Isolated Analog Programming Option
1 0-5V/0-10V Option PN IS510
PPM/C
Isolated Programming & Monitoring Connector
Setup and Operating Instructions
Maintenance
Fuse Rating
OUP
Top
Page
Image