NOTES:

*1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.

*2: Minimum current is guaranteed to maximum 0.4% of the rated output current.

*3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be de- scribed as 100-240Vac (50/60Hz).

*4: At 100/200V input voltage and maximum output power.

*5: From 85132Vac or 170265Vac, constant load.

*6: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.

*7: For load voltage change, equal to the unit voltage rating, constant input voltage.

*8: For 6V models the ripple is measured at 26V output voltage and full output current. For other models, the ripple is measured at 10100% output voltage and full output current.

*9: With rated, resistive load.

*10. For 6300V models: Measured with JEITA RC-9131A (1:1) probe For 600V model: Measured with (10:1) probe.

2.12 SUPPLEMENTAL CHARACTERISTICS

The supplemental characteristics give typical but non-warranted performance characteristics. The supplemental characteristics are useful in assessing applications for the power supply. Several kinds of supplemental characteristics are listed below.

1.Evaluation Data: Typical performance of the power supply.

2.Reliability Data: Reliability Performance of the power supply.

3.IEC1000 Data: Performance of the power supply under IEC1000 test conditions.

4.EMI Data: Typical EMI (conducted and radiated) performance of the power supply.

The supplemental characteristics data is held in each TDK-Lambda Americas Inc. sales and service facility. For further details please contact the TDK-Lambda Americas Inc. office nearest you.

11

83-507-013 Rev. D

Page 19