7.11.2Conditional Registers (continued) Table
BIT | Fault name | Fault symbol | Bit Set condition | Bit Reset condition |
0 (LSB) | Spare bit | SPARE | Fixed to zero | Fixed to zero |
|
|
|
|
|
1 | AC Fail | AC | AC fail has occurred. | The AC input returns to normal. |
2 | Over | OTP | OTP shutdown has | The power supply cools down. |
| temperature |
| occurred. |
|
3 | Foldback | FOLD | Foldback shutdown | The supply output is turned On by front |
|
|
| has occurred | panel button or OUT 1 command. |
4 | Over voltage | OVP | OVP shutdown has | The supply output is turned ON by front |
|
|
| occurred. | panel button or OUT 1 command. |
5 | Shut Off | SO | Rear panel J1 “Shut | Rear panel J1 “Shut Off” condition has |
|
|
| Off” condition has oc- | been removed. |
|
|
| curred. |
|
6 | Output Off | OFF | Front panel OUT but- | The supply output is turned On by front |
|
|
| ton pressed to Off. | panel button or OUT 1 command. |
7(MSB) | Enable | ENA | Rear panel J1 Enable | Rear panel J1 Enable terminals closed. |
|
|
| terminal |
|
|
|
| opened. |
|
Table |
|
|
BIT | Fault name | Fault symbol | Bit Set condition | Bit Reset condition |
0 (LSB) | Constant | CV | Output is On and the | Output is ON and the supply is not in |
| Voltage |
| supply in CV. | CV. |
1 | Constant | CC | Output is ON and the | Output is ON and the supply is not in |
| Current |
| supply in CC. | CC. |
2 | No Fault | NFLT | The power supply is | One or more faults are active and fault |
|
|
| operating normally or | reporting is enabled (using “FENAxx”). |
|
|
| fault reporting is not |
|
|
|
| enabled. |
|
|
|
| See “OUT n” com- |
|
|
|
| mand in Section 7.7.5. |
|
3 | Fault active | FLT | One or more faults are | Fault Event Register cleared (FEVE?). |
|
|
| enabled and occur. |
|
4 | AST | Supply is in Auto- | Supply is in | |
| Enabled |
| Restart mode (from | Front Panel or serial command). |
|
|
| Front Panel or serial |
|
|
|
| command). |
|
5 | Fold | FDE | Fold protection is | Fold protection disabled (from Front |
| Enabled |
| enabled (from Front | Panel or serial command). |
|
|
| Panel or serial |
|
|
|
| command). |
|
6 | Spare bit | SPARE | Fixed to zero. | Fixed to zero. |
7(MSB) | Local Mode | LCL | Supply in Local mode. | Supply in Remote mode or Local- |
|
|
|
| Lockout mode. |
7.11.3 Service Request: Enable and Event Registers
The conditional Registers are continuously monitored. When a change is detected in a register bit which is enabled, the power supply will generate an SRQ message.
The SRQ message is: “Inn” terminated by CR, where the nn is the power supply address. The SRQ will be generated either in Local or Remote mode.
64