7.10.6 | Status Control Commands |
| ||
Refer to Section |
| |||
# |
| Command |
| Description |
1 |
| STT? | Reads the complete power supply status. | |
|
|
| Returns ASCII characters representing the following data, separated by commas: | |
|
|
| MV<actual (measured) voltage> | PC<programmed (set) current> |
|
|
| PV<programmed (set) voltage> | SR<status register, |
|
|
| MC<actual (measured) current> | FR<fault register, |
|
|
| Example response: MV(45.201),PV(45), MC(4.3257), PC(10), SR(30), FR(00) | |
2 |
| FLT? | Reads Fault Conditional Register. Returns | |
3 |
| FENA | Set Fault Enable Register using | |
4 |
| FENA? | Reads Fault Enable Register. Returns | |
5 |
| FEVE? | Reads Fault Event Register. Returns | |
6 |
| STAT? | Reads Status Conditional Register. Returns | |
7 |
| SENA | Sets Status Enable Register using | |
8 |
| SENA? | Reads Status Enable Register. Returns | |
9 |
| SEVE? | Reads Status Event register. Returns |
7.11 STATUS, ERROR AND SRQ REGISTERS
7.11.1 General Description
This Section describes the various status error and SRQ registers structure. The registers can be read or set via the RS232/RS485 commands. When using the IEEE option, refer to the User’s Manual for GenesysTM Power Supply IEEE Programming Interface.
Refer to Fig.
62