8.3 ISOLATED PROGRAMMING & MONITORING CONNECTOR

Refer to Table 8-1 for detailed description of the rear panel Isolated Programming & Monitoring connector. To provide the lowest noise performance, it is recommended to use shielded-twisted pair wiring.

Refer to Fig.8-1 for description of the Isolated Analog Programming & Monitoring connector. Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.

1

2

3

4

5

6

7

8

Shield

+VPROG_ISO

+IPROG_ISO GND_ISO

Shield

+IMON_ISO

+VMON_ISO GND_ISO

Fig.8-1: Isolated Programming & Monitoring connector

Table 8-1: Detailed description of Isolated programming & Monitoring connector

 

 

 

Range 0-5/0-

Range 4-20mA

Terminal

Signal name

Function

10V

IS420 option

 

 

 

IS510 option

 

 

 

 

1

SHLD

Shield, connected internally to

Chassis ground

chassis of the power supply.

 

 

 

 

2

+VPROG_ISO

Output Voltage programming in-

0-5V/0-10V

4-20mA

put

 

 

 

 

3

+IPROG_ISO

Output Current programming in-

0-5V/0-10V

4-20mA

put

 

 

 

 

4

GND

Ground for programming signals.

Ground

Ground

 

 

 

 

 

5

GND

Ground for programming signals.

Ground

Ground

 

 

 

 

 

6

+VMON_ISO

Output voltage monitoring output

0-5V/0-10V

4-20mA

 

 

 

 

 

7

+IMON_ISO

Output current monitoring output

0-5V/0-10V

4-20mA

 

 

 

 

 

8

SHLD

Shield, connected internally to

Chassis ground

chassis of the supply.

 

 

 

 

CAUTION

When the Isolated Analog Option is installed, do not apply any signals to the non-isolated VPGM and IPGM (J1-9 and J1-10) pins. All other J1 features may be used normally. Refer to Section 4.5 for a description of J1 features.

69

83-507-013 Rev. D

Page 77
Image 77
TDK 750W, 1500W technical manual Isolated Programming & Monitoring Connector