| CHAPTER 2 | SPECIFICATIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
2.1 OUTPUT RATING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
MODEL |
| GEN |
|
|
| – | |||||||||||||||
1.Rated output voltage (*1) |
| V | 6 | 8 |
| 12.5 | 20 | 30 |
| 40 |
| – | 60 | 80 | 100 |
| 150 | 300 | 600 | ||
2.Rated output current 750W (*2) |
| A | 100 | 90 |
| 60 | 38 | 25 |
| 19 |
| – | 12.5 | 9.5 | 7.5 |
| 5 | 2.5 | 1.3 | ||
3.Rated output power 750W |
| W | 600 | 720 |
| 750 | 760 | 750 |
| 760 |
| – | 750 | 760 | 750 |
| 750 | 750 | 780 | ||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
MODEL |
| GEN |
|
| |||||||||||||||||
1.Rated output voltage (*1) |
| V | 6 | 8 |
| 12.5 | 20 | 30 |
| 40 |
| 50 | 60 | 80 | 100 |
| 150 | 300 | 600 | ||
2.Rated Output Current 1500W (*2) |
| A | 200 | 180 |
| 120 | 76 | 50 |
| 38 |
| 30 | 25 | 19 | 15 |
| 10 | 5 | 2.6 | ||
3.Rated output power 1500W |
| W | 1200 | 1440 | 1500 | 1520 | 1500 |
| 1520 |
| 1500 | 1500 | 1520 | 1500 |
| 1500 | 1500 | 1560 | |||
2.2 INPUT CHARACTERISTICS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| V | 6 | 8 |
| 12.5 | 20 | 30 |
| 40 |
| 50 | 60 | 80 | 100 |
| 150 | 300 | 600 | |||
1. | Input voltage/freq. (*3) |
| – | 85~265Vac continuous, |
|
|
|
|
|
|
|
|
|
| |||||||
2. | Input current (at 100/200Vac) |
| A | 10.5/5 for 750W model, 21/11 for 1500W models. |
|
|
|
|
|
|
|
|
|
| |||||||
3. | Power Factor |
| – | 0.99@100/200Vac, rated output power. |
|
|
|
|
|
|
|
|
|
|
|
| |||||
4. | 750W models Efficiency (*4) |
| % | 76/78 | 77/80 | 81/84 | 82/85 | 82/85 |
| 83/87 |
| 83/87 | 83/87 | 83/87 | 83/87 |
| 83/87 | 83/87 | 83/87 | ||
5. | 1500W models Efficiency (*4) |
| % | 77/79 | 78/81 | 82/85 | 83/86 | 83/86 |
| 84/88 |
| 84/88 | 84/88 | 84/88 | 84/88 |
| 84/88 | 84/88 | 84/88 | ||
6. | Inrush current at 100/200V |
| A | Less than 25A for 750W models, 50A for 1500W models. |
|
|
|
|
|
|
| ||||||||||
2.3 CONSTANT VOLTAGE MODE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| V | 6 | 8 |
| 12.5 | 20 | 30 |
| 40 |
| 50 | 60 | 80 | 100 |
| 150 | 300 | 600 | |||
1. | Max.Line regulation (*5) |
| – | 0.01% of rated output voltage +2mV |
|
|
|
|
|
|
|
|
|
|
|
| |||||
2. | Max.Load regulation (*6) |
| – | 0.01% of rated output voltage +2mV |
|
|
|
|
|
|
|
|
|
|
|
| |||||
3. Ripple and noise | mV | 60 | 60 |
| 60 | 60 | 60 |
| 60 |
| 60 | 60 | 80 | 80 |
| 100 | 150 | 300 | |||
4. Ripple r.m.s., 5Hz~1MHz (*10) |
| mV | 8 | 8 |
| 8 | 8 | 8 |
| 8 |
| 8 | 8 | 8 | 8 |
| 10 | 25 | 60 | ||
5. | Temperature coefficient |
| PPM/°C | 100PPM/°C of rated output voltage, following 30 minutes warm up |
|
|
|
|
|
|
| ||||||||||
6. | Temperature drift |
| – | 0.05% of rated Vout over 8hrs interval following 30 minutes |
|
|
| ||||||||||||||
7. Rem. Sense compensation/wire |
| V | 1 | 1 |
| 1 | 1 | 1.5 |
| 2 |
| 2 | 3 | 4 | 5 |
| 5 | 5 | 5 | ||
8. | mS |
|
|
|
| 80 |
|
|
|
|
|
|
| 150 |
| 250 | |||||
9. | mS | 10 |
|
| 50 |
|
|
|
| 80 |
|
| 150 |
| 250 | ||||||
|
|
| No load |
| 500 | 600 |
| 700 | 800 | 900 |
| 1000 |
| 1100 | 1100 | 1200 | 1500 |
| 2000 | 2500 | 4000 |
10. Transient response time |
| mS | Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated |
|
| ||||||||||||||||
|
|
|
|
| output current. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Output |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Less than 1mS for models up to and including 100V; 2mS for models above 100V. |
|
|
|
|
| |||||||||||
11. |
| mS | More than 20mS, 100Vac, rated output power. |
|
|
|
|
|
|
|
|
|
| ||||||||
2.4 CONSTANT CURRENT MODE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| V | 6 | 8 |
| 12.5 | 20 | 30 |
| 40 |
| 50 | 60 | 80 | 100 |
| 150 | 300 | 600 | |||
1. | Max.line regulation (*5) |
| – | 0.01% of rated output voltage +2mA |
|
|
|
|
|
|
|
|
|
|
|
| |||||
2. | Max.load regulation (*7) |
| – | 0.02% of rated output current +5mA |
|
|
|
|
|
|
|
|
|
|
|
| |||||
3. Ripple r.m.s. 5Hz~1MHz.750W (*8) | mA | 200 | 180 |
| 120 | 76 | 63 |
| 48 |
| – | 38 | 29 | 23 |
| 18 | 13 | 8 | |||
|
| 1500W (*8) | mA | 400 | 360 |
| 240 | 152 | 125 |
| 95 |
| 75 | 75 | 57 | 45 |
| 35 | 25 | 12 | |
4. | Temperature coefficient |
| PPM/°C | 100PPM/°C from rated output current, following 30 minutes |
|
|
|
|
|
| |||||||||||
5. | Temperature drift |
| – | 0.05% of rated lout over 8hrs interval following 30 minutes |
|
|
| ||||||||||||||
2.5 ANALOG PROGRAMMING AND MONITORING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
1.Vout voltage programming |
| – | 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; |
|
|
|
|
| |||||||||||||
2. | Iout voltage programming |
| – | 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; |
|
|
|
|
| ||||||||||||
3. | Vout resistor progrmming |
| – | 0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: |
|
|
| ||||||||||||||
4. | Iout resistor programming |
| – | 0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: |
|
|
| ||||||||||||||
5. | On/off control |
| – | By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic. |
|
|
|
|
|
| |||||||||||
6. | Output current monitor |
| – | 0~5V or 0~10V, user selectable. Accuracy: 1% |
|
|
|
|
|
|
|
|
|
| |||||||
7. | Output voltage monitor |
| – | 0~5V or 0~10V, user selectable. Accuracy: 1% |
|
|
|
|
|
|
|
|
|
| |||||||
8. | Power supply OK signal |
| – |
|
|
|
|
|
|
|
|
|
| ||||||||
9. | Parallel operation |
| – | Possible, up to 4 units in master/slave mode with single wire current balance connection. |
|
|
| ||||||||||||||
10. Series operation |
| – | Possible (with external diodes), up to 2 units. |
|
|
|
|
|
|
|
|
|
| ||||||||
11. CV/CC inicator |
| – | CV: TTL high (4~5V), source current: 10mA, CC: TTL low |
|
|
| |||||||||||||||
12. Enable/Disable |
| – | Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V. |
|
|
|
|
|
| ||||||||||||
13. Local/Remote analog control |
| – | By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local. |
|
|
|
|
| |||||||||||||
14. Local/remote analog indicator |
| – | Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA. |
|
|
|
9