5.14 SERIES OPERATION
Power supplies of the SAME MODEL can be connected in series to obtain increased output voltage. Split connection of the power supplies gives positive and negative output voltage.
CAUTION
Do not connected power supplies from different manufacturers in series or in parallel.
5.14.1 Series connection for increased output voltage
In this mode, two units are connected so that their outputs are summed. Set the Current of each power supply to the maximum that the load can handle without damage. It is recommended that di- odes be connected in parallel with each unit output to prevent reverse voltage during start up se- quence or in case one unit shuts down. Each diode should be rated to at least the power supply rated Output Voltage and Output Current. Refer to
WARNING
When power supplies are connected in series, and the load or one of the output terminals is grounded, no point may be at a greater potential of
+LS | +S |
| |
POWER | + | (*) | |
SUPPLY | - | ||
| |||
| |||
+LS | +S |
| |
POWER | + | (*) | |
SUPPLY | - | ||
| |||
|
+
LOAD
-
(*)Diodes are user supplied.
+LS | +S |
| |
POWER | + | (*) | |
SUPPLY | - | ||
| |||
| |||
+LS | +S |
| |
POWER | + | (*) | |
SUPPLY | - | ||
| |||
|
+
LOAD
-
|
|
Remote programming in series operation for increased output voltage:
1. Programming by external voltage:
The analog programming circuits of this power supply are referenced to the negative output potential. There- fore, the circuits used to control each series connected unit must be separated and floated from each other.
2.Using the SO function and PS_OK signal: The
39