Model 9060Z Manual

0x41 Special Instruction Function

This command allows you to interact with the transmitter allowing access to functionality that would otherwise only be accessible via the keypad. The request length will vary from one command to the next depending on what arguments are required. Requests are formed the same as other modbus requests:

1 byte

1 byte

1 byte

0 ‐4 bytes

2 bytes

slave address

command code

function code

arguments

checksum

Function Code

Command

Arguments

0x01

Accept All Active Alarms

none

0x02

remote set key down

1 byte keymask

0x03

remote reset key down

1 byte keymask

0x04

Initiate Probe Impedance Check

none

0x05

Set Internal Clock

4 byte rtc*

* date expressed as seconds since 1‐Jan 2004

67