1 PRECAUTIONS FOR SAFETY

Ensure that all Local, National and International regulations are satisfied.

Read this “PRECAUTIONS FOR SAFETY” carefully before Installation.

The precautions described below include the important items regarding safety. Observe them without fail.

After the installation work, perform a trial operation to check for any problem.

Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.

Turn off the main power supply switch (or breaker) before the unit maintenance.

Ask the customer to keep the Installation Manual together with the Owner’s Manual.

CAUTION

New Refrigerant Air Conditioner Installation

THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT DESTROY OZONE LAYER.

The characteristics of R410A refrigerant are ; easy to absorb water, oxidizing membrane or oil, and its pressure is approx. 1.6 times higher than that of refrigerant R22. Accompanied with the new refrigerant, refrigerating oil has also been changed. Therefore, during installation work, be sure that water, dust, former refrigerant, or refrigerating oil does not enter the refrigerating cycle.

To prevent charging an incorrect refrigerant and refrigerating oil, the sizes of connecting sections of charging port of the main unit and installation tools are charged from those for the conventional refrigerant.

Accordingly the exclusive tools are required for the new refrigerant (R410A).

For connecting pipes, use new and clean piping designed for R410A, and please care so that water or dust does not enter. Moreover, do not use the existing piping because there are problems with pressure-resistance force and impurity in it.

ENGLISH

CAUTION

To Disconnect the Appliance from Main Power Supply.

This appliance must be connected to the main power supply by means of a switch with a contact separation of at least 3 mm.

WARNING

Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner.

Inappropriate installation may result in water leakage, electric shock or fire.

Turn off the main power supply switch or breaker before attempting any electrical work.

Make sure all power switches are off. Failure to do so may cause electric shock.

Connect the connecting wire correctly.

If the connecting wire is connected in a wrong way, electric parts may be damaged.

When moving the air conditioner for the installation into another place, be very careful not to enter any gaseous matter other than the specified refrigerant into the refrigeration cycle.

If air or any other gas is mixed in the refrigerant, the gas pressure in the refrigeration cycle becomes abnormally high and it resultingly causes pipe burst and injuries on persons.

Do not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches.

Exposure of unit to water or other moisture before installation may cause a short-circuit of electrical parts.

Do not store it in a wet basement or expose to rain or water.

2

Page 5
Image 5
Toshiba MMU-AP0071YH installation manual Precautions for Safety, New Refrigerant Air Conditioner Installation

MMU-AP0071YH specifications

The Toshiba MMU-AP0071YH is an advanced motion control solution tailored for precise applications in various sectors, including industrial automation and robotics. This model exemplifies Toshiba's commitment to innovation and reliability, integrating cutting-edge technologies to streamline processes and enhance system performance.

One of the standout features of the MMU-AP0071YH is its superior motion control capabilities. It offers advanced servo control technology, ensuring highly accurate positioning and smooth motion transitions. This precision is critical for applications where even minor deviations can impact the overall system performance, such as in CNC machinery and robotic arms.

The MMU-AP0071YH is designed with flexibility in mind. It supports a wide range of interfaces, including EtherCAT, CANopen, and RS-232, allowing seamless integration with various systems and devices. This versatility facilitates easy implementation in existing setups, enabling manufacturers to upgrade their equipment without extensive modifications.

Another significant characteristic of the MMU-AP0071YH is its robust safety features. Safety is paramount in industrial environments, and Toshiba has incorporated multiple safety functions, such as Safe Torque Off (STO) and Safe Stop 1 (SS1). These features ensure the system can detect faults and respond appropriately to prevent accidents and protect both the machinery and operators.

Furthermore, the device is built to withstand demanding operational conditions. The MMU-AP0071YH is characterized by a compact and sturdy design, which is essential for environments that require high durability. The quality of the materials used in its construction also plays a vital role in its ability to operate effectively under various conditions.

In addition to its technical capabilities, the MMU-AP0071YH features user-friendly software tools that allow operators to configure, monitor, and manage motion tasks effortlessly. The user interface is intuitive, enabling engineers and technicians to access critical parameters quickly, thus optimizing performance and reducing downtime.

Overall, the Toshiba MMU-AP0071YH combines precision, versatility, and safety, making it a compelling choice for industries seeking reliable motion control solutions. Its innovative technology and robust design not only enhance operational efficiency but also contribute to the long-term sustainability of various manufacturing processes.