2 SELECTION OF INSTALLATION PLACE

In case of wireless type

The wireless remote controller can be operated up to a maximum of 8 m from the infra-red receiver.

Therefore ensure that the remote controller will be mounted and used within this stated parameter.

To prevent malfunction do not mount or operate in a location that is subjected to either a fluorescent lamp or direct sunlight.

A maximum of 6 indoor units with wireless remote controller can be installed within the same room.

3 INSTALLATION OF INDOOR UNIT

22

WARNING

The installation of the air conditioning unit must be positioned in a location that can sufficiently support its weight

 

and give protection against adverse environmental conditions.

Failure to do so may result in unit damage and possible human injury.

Any incomplete installation may also cause possible risk of human injury.

Unpack the package, take out the product and then place it on the floor so that the same surface directs underneath as it is placed in the package.

Never put the products taken out from the packing box in a

pile, or put other load on them; otherwise there is a

OK

NO GOOD

possibility to damage electric parts, fan parts, draining

 

 

mechanism, and etc.

 

 

If the both sides are turned over, a deformation of mounting metal of the ceiling panel which is sold separately, etc may be caused. Accordingly the product may be damaged and the installation becomes impossible in some cases.

REQUIREMENT

Strictly comply to the following rules to prevent damage of the indoor units and human injury.

Do not place heavy objects on the indoor unit. (Even when units are still packaged)

Always carry the unit as packaged from the factory wherever possible.

If carrying in the indoor unit unpacked by necessity, be sure to use buffering cloth, etc. to prevent damaging the unit.

To move the indoor unit, hold the hanging brackets (4 positions) only.

Do not apply force to other parts (refrigerant pipe, drain pan, foamed parts, or resin parts etc.).

• To be carried by two or more persons. Do not strap the unit in positions other than that stated.

Dimensional view

 

1000 or more

1000 or more

595 to 660 Ceiling open dimension

15 or more

 

 

Obstacle

 

1000 or more

15 or more

Space required for

installation and servicing

207

175

149

 

 

 

 

 

 

64

29

142

64

368.5

 

Knockout for 100 diameter

 

fresh air intake

 

145.5

Bottom face

700 Panel external dimension

93

595 to 660 Ceiling open dimension

of ceiling

 

 

 

525 Hanging bolt pitch

 

 

 

105

70

 

 

 

235

dimension

 

 

105

external

 

 

235

575 Unit

 

Ø162

 

 

4 screw holes

Electric parts box

320.5

 

 

(For 4 mm tapping screw)

 

For 150 diameter

575 Unit external dimension

 

 

branch duct knockout

 

 

square hole

 

 

Bottom face of ceiling

 

 

 

 

 

 

 

200

 

 

 

 

 

Check port

 

 

dimension

 

200

(

 

450)

 

200

Check port

 

 

 

 

 

 

(o450)

 

 

 

Check port

 

 

 

 

 

 

 

(

450)

 

Ceiling660open

 

Drain-up standing-up size

 

 

300 or less

Stand-up

627.5

lessor

up-Stand

lessor850

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling

 

 

 

 

to

Note)

 

 

 

 

 

 

 

595

 

 

 

 

 

 

 

As ABS is used for the drain discharge port of the main unit,

 

the vinyl chloride paste cannot be used.

 

Use the flexible hose (Band fix) included in the package.

 

 

 

4

2.7

 

 

Wired remote

 

 

 

120

 

 

controller

 

 

 

 

 

(RBC-AMT31E)

 

 

 

 

 

 

 

 

120

 

16

 

 

 

 

 

 

 

 

 

268

27

 

 

 

220.5

 

 

 

Drain discharge port

145.5

 

 

 

Hanging bolt

 

 

134

 

Bottom face

 

 

 

 

of ceiling

 

M10 or W3/8

 

 

63

 

 

local arrange

 

 

Ceiling panel

 

 

 

 

 

Hanging525bolt pitch Ceiling660to595open dimension externalPanel700 dimension

105214 256

 

 

177

14842

 

21120

158142

 

 

 

Ø162

 

 

 

 

Refrigerant pipe

97.5

 

Wiring connection

 

 

 

 

 

55

port

 

 

(Liquid) Ø6.4

 

 

 

 

 

 

 

 

For 150 diameter 70 105 93

branch duct

 

 

 

 

 

 

 

 

139.5

knockout square hole

 

 

 

 

 

Refrigerant pipe (Gas)

190.5

0151, 0181MH : Ø12.7

 

 

 

 

0071 to 0121MH : Ø9.5

 

 

 

 

Page 22
Image 22
Toshiba MMU-AP0091MH, MMU-AP0181MH, MMU-AP0151MH Installation of Indoor Unit, Case of wireless type, Dimensional view

MMU-AP0181MH, MMU-AP0071MH, MMU-AP0091MH, MMU-AP0151MH, MMU-AP0121MH specifications

The Toshiba MMU-AP series, consisting of models MMU-AP0121MH, MMU-AP0151MH, MMU-AP0091MH, MMU-AP0071MH, and MMU-AP0181MH, represents a significant advancement in the realm of power management and energy efficiency for a variety of applications. These modules are designed to optimize performance while ensuring minimal energy consumption, making them suitable for both commercial and industrial uses.

One of the standout features of the MMU-AP series is its intelligent power management technology. This feature allows for adaptive energy distribution based on real-time demands. By leveraging precise control algorithms, the modules can adjust their output to match the specific requirements of connected devices, ultimately leading to reduced power loss and increased efficiency. This adaptability not only benefits end-users by lowering operational costs but also contributes to a greener environment by minimizing waste.

The versatility of the MMU-AP series is evident in its wide range of operational capabilities. These power modules are designed to work effectively in various voltage levels and load conditions. With input voltage ranges suitable for standard industrial environments, they can easily be integrated into existing systems, enhancing overall functionality without requiring extensive modifications.

Moreover, the compact design of the MMU-AP modules is another notable characteristic. Their size and light weight facilitate easier installation and integration into tight spaces, making them ideal for applications where real estate is a premium. This compact profile does not compromise performance, as these modules are engineered to deliver robust power output while maintaining thermal efficiency.

In terms of reliability, the MMU-AP series is built with high-grade components that withstand harsh operating conditions. With features such as over-voltage protection, short-circuit protection, and thermal shutdown capabilities, users can trust that their equipment would operate safely and efficiently, thereby extending the lifespan of both the power modules and the devices they serve.

Finally, Toshiba’s commitment to innovation ensures that the MMU-AP series incorporates cutting-edge technology. The series supports communication protocols that enable seamless integration with smart systems, paving the way for advanced monitoring and control functions. This levels up the user experience, providing insights into performance and diagnostics that are crucial for uptime and reliability in demanding environments.

In conclusion, the Toshiba MMU-AP series offers a blend of efficiency, adaptability, and advanced technology, making it a valuable asset for various industrial and commercial applications. Its intelligent design and robust features ensure that users can optimize energy use while maintaining high performance and reliability.