Toshiba MMU-AP0091MH, MMU-AP0181MH Make a note of the setup contents. Item code list Example

Models: MMU-AP0181MH MMU-AP0071MH MMU-AP0091MH MMU-AP0151MH MMU-AP0121MH

1 117
Download 117 pages 2 Kb
Page 112
Image 112

<Make a note of the setup contents. (Item code list (Example))>

DN

Item

Memo

Setup at shipment from factory

 

 

 

 

 

 

 

 

01

Filter sign lighting time

 

According to type

 

 

 

 

 

 

 

 

 

 

02

Dirty condition of filter

 

0000: Standard

 

 

 

 

 

 

 

 

 

 

03

Central control address

 

0099: Undefined

 

 

 

 

 

 

 

 

 

 

06

Heating inlet temp. shift

 

0002: +2°C (Floor standing: 0)

 

 

 

 

 

 

 

 

 

 

0d

Cooling Auto mode existence

 

0001: No auto mode cooling/heating

(

* Automatic selection

)

 

 

 

 

by connected

0F

Cooling only/Heat pump select

 

0000: Heat pump

 

 

outdoor unit

 

10

Type

 

According to model type

 

 

 

 

 

 

 

 

 

 

11

Indoor unit capacity

 

According to capacity code

 

 

 

 

 

 

 

 

 

 

12

Line address

 

0099: Undefined

 

 

 

 

 

 

 

 

 

 

13

Indoor unit address

 

0099: Undefined

 

 

 

 

 

 

 

 

 

 

14

Group address

 

0099: Undefined

 

 

 

 

 

 

 

 

 

 

19

Flap type (Air direction adjustment)

 

According to type

 

 

 

 

 

 

 

 

 

 

1E

Temp. width between cooling and heating

 

0003: 3 deg (Ts ± 1.5)

 

 

 

automatic selective control points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

Automatic restart from power failure

 

0000: None

 

 

 

 

 

 

 

 

 

 

2E

HA terminal (T10) selection

 

0000: Normal

 

 

 

 

 

 

 

 

 

 

32

Sensor select

 

0000: Body sensor

 

 

 

 

 

 

 

 

 

 

5d

High ceiling selection

 

0000: Standard

 

 

 

 

 

 

 

 

 

 

60

Timer setup (Wired remote controller)

 

0000: Possible

 

 

 

 

 

 

 

 

 

 

Type

Item code [10]

Setup

Type

Model

data

abb. name

 

 

 

 

0000

1-way Air Discharge Cassette

MMU-AP✻✻✻SH

 

 

 

0001

4-way Air Discharge Cassette

MMU-AP✻✻✻H

 

 

 

0002

2-way Air Discharge Cassette

MMU-AP✻✻✻WH

 

 

 

0003

1-way Air Discharge Cassette

MMU-AP✻✻✻YH

(Compact type)

 

 

 

 

 

0004

Concealed Duct Standard

MMD-AP✻✻✻BH

 

 

 

0005

Slim Duct

MMD-AP✻✻✻SPH

MMD-AP✻✻✻SH

 

 

 

 

 

0006

Concealed Duct High Static Pressure

MMD-AP✻✻✻H

 

 

 

0007

Under Ceiling

MMC-AP✻✻✻H

 

 

 

0008

High Wall

MMK-AP✻✻✻H

 

 

 

0009

 

 

 

 

 

0010

Floor Standing Cabinet

MML-AP✻✻✻H

 

 

 

0011

Floor Standing Concealed

MML-AP✻✻✻BH

 

 

 

0012

(Floor Standing 8, 10HP)

MMF-AP ∗∗∗ H

 

 

 

0013

Floor Standing (Below 6HP)

MMF-AP✻✻✻H

 

 

 

0014

Compact 4-way Air Discharge

MMU-AP✻✻✻MH

Cassette

 

 

 

 

 

Indoor unit capacity

Item code [11]

Setup data

Model

Setup data

Model

 

 

 

 

0000

Invalid

0016

 

 

 

 

0001

007 type

0017

048 type

 

 

 

 

0002

0018

056 type

 

 

 

 

0003

009 type

0019

 

 

 

 

0004

0020

 

 

 

 

0005

012 type

0021

072 type

 

 

 

 

0006

0022

 

 

 

 

0007

015 type

0023

096 type

 

 

 

 

0008

0024

 

 

 

 

0009

018 type

0025

 

 

 

 

0010

0026

 

 

 

 

0011

024 type

0027

 

 

 

 

0012

027 type

0028

 

 

 

 

0013

030 type

~

 

 

 

 

0014

0034

 

 

 

 

0015

036 type

 

 

 

 

 

 

The initial setup value of EEPROM installed on the service P.C. board