Toshiba MMU-AP0151MH, MMU-AP0181MH Adjustment of Wind Direction, How to set up the air direction

Models: MMU-AP0181MH MMU-AP0071MH MMU-AP0091MH MMU-AP0151MH MMU-AP0121MH

1 117
Download 117 pages 2 Kb
Page 16
Image 16

3-7. Adjustment of Wind Direction

While the air conditioner stops, the horizontal flap (Up/Down air direction adjustment plate) automati- cally directs upward.

While the air conditioner is in ready status for heating, the horizontal flap (Up/Down air direction

adjustment plate) directs upward. The swinging operation starts after heating ready status has been

cleared, but “SWING ” is displayed on the remote controller even if the status is ready to heating.

How to set up the air direction

Push

SWING/FIX

1 Every pushing the button, the air direction changes.

button during operation.

In Heating operation

 

In Cooling / Dry operation

 

Set the horizontal flap (Up/Down

 

Set the horizontal flap (Up/Down

 

air direction adjustment plate)

 

air direction adjustment plate)

 

downward. If directing it upward,

 

upward. If directing it downward,

 

the hot air may not come to the

Initial setup

the dew may fall on near the air

Initial setup

foot come to the foot.

air outlet port or it drips.

 

 

How to start swinging

2 Push SWING/FIX button.

Set direction of the horizontal flap (Up/Down air

TEMP.

ON / OFF

direction adjustment plate) to the lowest position and then push SWING/FIX button again.

[SWING ] is displayed and the air direction automatically changes upward/downward.

In case when one remote controller controls the multiple indoor units, each indoor unit can be se- lected and its air direction can be set up.

How to stop swinging

3 Push SWING/FIX button again during swinging of the horizontal flap.

 

TIMER SET

 

TIME

FILTER

 

RESET TEST

SET CL

1, 2, 3

FAN MODE

SWING/FIX VENT

UNIT

4

The horizontal flap can be stopped at the desired position. After then the air direction can be again set up from the uppermost position by pushing SWING/FIX button.

*While the horizontal flap is set downward in cool- ing/drying operation, it does not stop.

If stopping the horizontal flap which directs down- ward during swinging, it stops after moving to the

3rd position from the top position.

4 UNIT

UNIT

To set up the air direction individually, push button to display each indoor unit No. in a group control. Then set up the air direction to a displayed indoor unit.

If there is no display, all the indoor units can be operated collectively.

• Every pushing UNIT button, the display exchanges as shown in the figure.

No display Unit No. 1-1 Unit No. 1-2

Unit No. 1-4 Unit No. 1-3

In FAN operation

In all modes

Series of operation

Initial setup

Display when stopping the swing

Fan/HeatCool/Dry

operationoperation

16

Page 16
Image 16
Toshiba MMU-AP0151MH, MMU-AP0181MH Adjustment of Wind Direction, How to set up the air direction, How to start swinging

MMU-AP0181MH, MMU-AP0071MH, MMU-AP0091MH, MMU-AP0151MH, MMU-AP0121MH specifications

The Toshiba MMU-AP series, consisting of models MMU-AP0121MH, MMU-AP0151MH, MMU-AP0091MH, MMU-AP0071MH, and MMU-AP0181MH, represents a significant advancement in the realm of power management and energy efficiency for a variety of applications. These modules are designed to optimize performance while ensuring minimal energy consumption, making them suitable for both commercial and industrial uses.

One of the standout features of the MMU-AP series is its intelligent power management technology. This feature allows for adaptive energy distribution based on real-time demands. By leveraging precise control algorithms, the modules can adjust their output to match the specific requirements of connected devices, ultimately leading to reduced power loss and increased efficiency. This adaptability not only benefits end-users by lowering operational costs but also contributes to a greener environment by minimizing waste.

The versatility of the MMU-AP series is evident in its wide range of operational capabilities. These power modules are designed to work effectively in various voltage levels and load conditions. With input voltage ranges suitable for standard industrial environments, they can easily be integrated into existing systems, enhancing overall functionality without requiring extensive modifications.

Moreover, the compact design of the MMU-AP modules is another notable characteristic. Their size and light weight facilitate easier installation and integration into tight spaces, making them ideal for applications where real estate is a premium. This compact profile does not compromise performance, as these modules are engineered to deliver robust power output while maintaining thermal efficiency.

In terms of reliability, the MMU-AP series is built with high-grade components that withstand harsh operating conditions. With features such as over-voltage protection, short-circuit protection, and thermal shutdown capabilities, users can trust that their equipment would operate safely and efficiently, thereby extending the lifespan of both the power modules and the devices they serve.

Finally, Toshiba’s commitment to innovation ensures that the MMU-AP series incorporates cutting-edge technology. The series supports communication protocols that enable seamless integration with smart systems, paving the way for advanced monitoring and control functions. This levels up the user experience, providing insights into performance and diagnostics that are crucial for uptime and reliability in demanding environments.

In conclusion, the Toshiba MMU-AP series offers a blend of efficiency, adaptability, and advanced technology, making it a valuable asset for various industrial and commercial applications. Its intelligent design and robust features ensure that users can optimize energy use while maintaining high performance and reliability.