Toshiba MMU-AP0151MH Tools, General tools Conventional tools can be used, Used tool Usage

Models: MMU-AP0181MH MMU-AP0071MH MMU-AP0091MH MMU-AP0151MH MMU-AP0121MH

1 117
Download 117 pages 2 Kb
Page 6
Image 6

4. Tools

(1)Required Tools for R410A

Mixing of different types of oil may cause a trouble such as generation of sludge, clogging of capillary, etc. Accordingly, the tools to be used are classified into the following three types.

1)Tools exclusive for R410A (Those which cannot be used for conventional refrigerant (R22))

2)Tools exclusive for R410A, but can be also used for conventional refrigerant (R22)

3)Tools commonly used for R410A and for conventional refrigerant (R22)

The table below shows the tools exclusive for R410A and their interchangeability.

Tools exclusive for R410A (The following tools for R410A are required.)

Tools whose specifications are changed for R410A and their interchangeability

 

 

 

 

R410A

Conventional air

 

 

 

air conditioner installation

conditioner installation

No.

Used tool

Usage

 

 

 

 

Existence of

 

Whether conven-

Whether new equipment

 

 

 

 

 

 

 

new equipment

 

tional equipment can

can be used with

 

 

 

for R410A

 

be used

conventional refrigerant

 

 

 

 

 

 

 

Q

Flare tool

Pipe flaring

Yes

 

*(Note 1)

Yes

 

 

 

 

 

 

 

 

Copper pipe gauge for

Flaring by conventional

 

 

 

 

R

adjusting projection

Yes

 

*(Note 1)

*(Note 1)

flare tool

 

 

margin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

Torque wrench

Connection of flare nut

Yes

 

No

No

 

 

 

 

 

 

 

T

Gauge manifold

Evacuating, refrigerant

Yes

 

No

No

 

 

 

 

 

charge, run check, etc.

 

U

Charge hose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

Vacuum pump adapter

Vacuum evacuating

Yes

 

No

Yes

 

 

 

 

 

 

 

W

Electronic balance for

Refrigerant charge

Yes

 

Yes

Yes

refrigerant charging

 

 

 

 

 

 

 

 

X

Refrigerant cylinder

Refrigerant charge

Yes

 

No

No

 

 

 

 

 

 

 

Y

Leakage detector

Gas leakage check

Yes

 

No

Yes

 

 

 

 

 

 

 

Y

Charging cylinder

Refrigerant charge

(Note 2)

 

No

No

 

 

 

 

 

 

 

(Note 1) When flaring is carried out for R410A using the conventional flare tools, adjustment of projection margin is necessary. For this adjustment, a copper pipe gauge, etc. are necessary.

(Note 2) Charging cylinder for R410A is being currently developed.

General tools (Conventional tools can be used.)

In addition to the above exclusive tools, the following equipments which serve also for R22 are necessary as the general tools.

(1)

Vacuum pump

(7)

Screwdriver (+, –)

 

Use vacuum pump by

(8)

Spanner or Monkey wrench

 

attaching vacuum pump adapter.

(9)

Hole core drill

(2)

Torque wrench

(10)

Hexagon wrench (Opposite side 4mm)

(3)

Pipe cutter

(11)

Tape measure

(4)

Reamer

(12)

Metal saw

 

 

(5)Pipe bender

(6)Level vial

Also prepare the following equipments for other installation method and run check.

(1)

Clamp meter

(3)

Insulation resistance tester

(2)

Thermometer

(4)

Electroscope

6

Page 6
Image 6
Toshiba MMU-AP0151MH Tools, General tools Conventional tools can be used, Used tool Usage, Conditioner installation

MMU-AP0181MH, MMU-AP0071MH, MMU-AP0091MH, MMU-AP0151MH, MMU-AP0121MH specifications

The Toshiba MMU-AP series, consisting of models MMU-AP0121MH, MMU-AP0151MH, MMU-AP0091MH, MMU-AP0071MH, and MMU-AP0181MH, represents a significant advancement in the realm of power management and energy efficiency for a variety of applications. These modules are designed to optimize performance while ensuring minimal energy consumption, making them suitable for both commercial and industrial uses.

One of the standout features of the MMU-AP series is its intelligent power management technology. This feature allows for adaptive energy distribution based on real-time demands. By leveraging precise control algorithms, the modules can adjust their output to match the specific requirements of connected devices, ultimately leading to reduced power loss and increased efficiency. This adaptability not only benefits end-users by lowering operational costs but also contributes to a greener environment by minimizing waste.

The versatility of the MMU-AP series is evident in its wide range of operational capabilities. These power modules are designed to work effectively in various voltage levels and load conditions. With input voltage ranges suitable for standard industrial environments, they can easily be integrated into existing systems, enhancing overall functionality without requiring extensive modifications.

Moreover, the compact design of the MMU-AP modules is another notable characteristic. Their size and light weight facilitate easier installation and integration into tight spaces, making them ideal for applications where real estate is a premium. This compact profile does not compromise performance, as these modules are engineered to deliver robust power output while maintaining thermal efficiency.

In terms of reliability, the MMU-AP series is built with high-grade components that withstand harsh operating conditions. With features such as over-voltage protection, short-circuit protection, and thermal shutdown capabilities, users can trust that their equipment would operate safely and efficiently, thereby extending the lifespan of both the power modules and the devices they serve.

Finally, Toshiba’s commitment to innovation ensures that the MMU-AP series incorporates cutting-edge technology. The series supports communication protocols that enable seamless integration with smart systems, paving the way for advanced monitoring and control functions. This levels up the user experience, providing insights into performance and diagnostics that are crucial for uptime and reliability in demanding environments.

In conclusion, the Toshiba MMU-AP series offers a blend of efficiency, adaptability, and advanced technology, making it a valuable asset for various industrial and commercial applications. Its intelligent design and robust features ensure that users can optimize energy use while maintaining high performance and reliability.