7-6. 7-Segment Display Function

n7-segment display on the outdoor unit (Interface P.C. board)

On the interface control P.C. board, 7-segment LED to check the operating status is provided on the control P.C. board.

The displayed contents are changed by combining the setup numbers of the rotary switches (SW01, SW02, and SW03) on P.C. board.

7-segment

 

7-segment

display A

 

display B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd. 1st. 3rd. 2nd. 1st.

place place place place place

Interface P.C. board

SW06

 

SW07

SW08

SW09

CN30

CN31

 

 

 

SW05

SW15

 

 

CN32

SW04

 

 

D600

D601

D602

D603

D604

Display A

 

 

 

 

 

 

 

SW01

SW02

SW03

 

Display B

SW06

 

SW07

SW08

SW09

CN30

CN31

 

 

 

SW05

SW15

 

 

CN32

SW04

 

 

D600

D601

D602

D603

D604

Display A

 

 

 

 

 

 

 

SW01

SW02

SW03

 

Display B

uCheck procedure in case of stop with trouble

When the system stopped due to a trouble of the outdoor unit, execute a check in the following procedure.

1. Open the panel of the outdoor unit, and then check the 7-segment display.

The check code is displayed at the right side of 7-segment display B.

[U1] [¡¡¡] ([¡¡¡]: Check code)

Switch setup when confirming the check code: SW01 [1], SW02 [1], SW03 [1]

However the check code [¡¡¡] is displayed for 3 seconds and the auxiliary code [¡¡¡] for 1 second are alternately displayed if an auxiliary code is provided.

2.Confirm the check code, and then conduct the check operation based on the procedure of each check code diagnosis.

3.[U1] [E28] on 7-segment display means a trouble on the follower unit.

Push the push-switch SW04 on the header unit for several seconds. (2 seconds or more)

As only the fan of the outdoor unit with a trouble drives, open the panel of the corresponding unit, and then confirm the check code displayed with 7-segment.

4.Perform the check operation based on the procedure of each check code diagnosis.

How to read the check monitor

<7-segment display>

0 1 2 3 4 5 6 7 8 9 A b C d E F H J L P

a c e G h i n o r S t V y – u

89

Page 89
Image 89
Toshiba MMU-AP0121MH, MMU-AP0181MH Segment Display Function, Segment display on the outdoor unit Interface P.C. board

MMU-AP0181MH, MMU-AP0071MH, MMU-AP0091MH, MMU-AP0151MH, MMU-AP0121MH specifications

The Toshiba MMU-AP series, consisting of models MMU-AP0121MH, MMU-AP0151MH, MMU-AP0091MH, MMU-AP0071MH, and MMU-AP0181MH, represents a significant advancement in the realm of power management and energy efficiency for a variety of applications. These modules are designed to optimize performance while ensuring minimal energy consumption, making them suitable for both commercial and industrial uses.

One of the standout features of the MMU-AP series is its intelligent power management technology. This feature allows for adaptive energy distribution based on real-time demands. By leveraging precise control algorithms, the modules can adjust their output to match the specific requirements of connected devices, ultimately leading to reduced power loss and increased efficiency. This adaptability not only benefits end-users by lowering operational costs but also contributes to a greener environment by minimizing waste.

The versatility of the MMU-AP series is evident in its wide range of operational capabilities. These power modules are designed to work effectively in various voltage levels and load conditions. With input voltage ranges suitable for standard industrial environments, they can easily be integrated into existing systems, enhancing overall functionality without requiring extensive modifications.

Moreover, the compact design of the MMU-AP modules is another notable characteristic. Their size and light weight facilitate easier installation and integration into tight spaces, making them ideal for applications where real estate is a premium. This compact profile does not compromise performance, as these modules are engineered to deliver robust power output while maintaining thermal efficiency.

In terms of reliability, the MMU-AP series is built with high-grade components that withstand harsh operating conditions. With features such as over-voltage protection, short-circuit protection, and thermal shutdown capabilities, users can trust that their equipment would operate safely and efficiently, thereby extending the lifespan of both the power modules and the devices they serve.

Finally, Toshiba’s commitment to innovation ensures that the MMU-AP series incorporates cutting-edge technology. The series supports communication protocols that enable seamless integration with smart systems, paving the way for advanced monitoring and control functions. This levels up the user experience, providing insights into performance and diagnostics that are crucial for uptime and reliability in demanding environments.

In conclusion, the Toshiba MMU-AP series offers a blend of efficiency, adaptability, and advanced technology, making it a valuable asset for various industrial and commercial applications. Its intelligent design and robust features ensure that users can optimize energy use while maintaining high performance and reliability.