Toshiba RAV-SM1603ATZG-E, RAV-SM1603DT-A, RAV-SM1603ATZ-E Outdoor Unit, 141, Xrequirementx

Models: RAV-SM1403DT-A RAV-SM1603ATZ-E RAV-SM1603ATZG-E RAV-SM1603DT-A

1 157
Download 157 pages 61.3 Kb
Page 141
Image 141
14-2. Outdoor Unit

14-2. Outdoor Unit

No.

Part name

 

Procedure

Remarks

 

 

 

 

 

 

 

1

Common

 

 

 

 

Front panel

 

 

 

 

 

procedure

 

XREQUIREMENTX

 

 

 

 

 

 

Be sure to put on the gloves at any process; otherwise an

 

 

 

injury will be caused by the parts, etc.

 

 

 

 

 

 

 

 

 

 

1. Detachment

 

 

1)

Stop operation of the air conditioner and then turn off

 

 

 

 

switch of the breaker.

 

 

2)

Remove the front panel.

 

 

 

 

(Hexagonal screws Ø4 × 10, 2 pcs.)

 

 

 

 

• Remove the screws and then remove the front panel

 

 

 

 

by pulling it downward.

 

 

3)

Remove the power supply cable and the indoor/outdoor

 

 

 

 

connecting wire from the cord clamp and the terminal.

 

 

4)

Remove the top plate.

 

 

 

 

(Hexagonal screws Ø4 × 10, 5 pcs.)

 

 

2. Attachment

 

 

1)

Attach the top plate.

 

 

 

 

(Hexagonal screws Ø4 × 10, 5 pcs.)

 

 

2)

Connect the power supply cable and the indoor/outdoor

 

 

 

 

connecting wire to the terminal and then fix them with

 

 

 

 

the cord clamp.

Top plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XREQUIREMENTX

 

For the power supply cable and the indoor/outdoor connecting wire, be sure fix them using the bundling band (procured locally) along the crossover pipe so that they do not come to contact with the compressor, valve at gas side, pipe at gas side and discharge pipe.

3)Attach the front panel.

(Hexagonal screws Ø4 × 10, 2 pcs.)

2Air outlet 1. Detachment

cabinet

1)

Carry out work of 1 of 1 .

Heat exchanger

Partition plate

Reactor assembly

 

2)

Remove screws for the air outlet cabinet and the

 

 

 

 

 

partition board. (ST1T Ø4 × 8, 4 pcs.)

Motor base

Air outlet

 

3)

Remove screws for the air outlet cabinet and the bottom

 

cabinet

 

 

plate. (Hexagonal screws Ø4 × 10, 2 pcs.)

 

 

4)Remove screws for the air outlet cabinet and the motor base. (ST1T Ø4 × 8, 2 pcs.)

5)Remove screw for the air outlet cabinet and the heat exchanger. (ST1T Ø4 × 8, 1 pc.)

6)Remove screws for the air outlet cabinet and the fin

guard. (Hexagonal screws Ø4 × 10, 2 pcs.)

7) Remove screws for the air outlet cabinet and the reactor

 

assembly. (ST1T Ø4 × 8, 2 pcs.)

Fin guard

3Side cabinet 1. Detachment

1) Carry out work of 1 of 1 .

Side cabinet

2)Remove the screws which fix the inverter assembly and the side cabinet. (ST1T Ø4 × 8, 2 pcs.)

3)Remove the screws which fix the side cabinet and the valve fixing plate. (ST1T Ø4 × 8, 2 pcs.)

4)Remove screws which fix the side cabinet and the piping panel (Rear). (Hexagonal screws Ø4 × 10, 2 pcs.)

5)Remove screw for the side cabinet and the bottom plate. (Hexagonal screws Ø4 × 10, 1 pc.)

6)Remove screws for the side cabinet and the fin guard (Heat exchanger). (Hexagonal screws Ø4 × 10, 5 pcs.)

Valve fixing plate