1-1-3. Concealed Duct Type <Twin type>

 

 

Indoor unit 1

 

RAV-

SM802BT-E

 

 

 

 

 

 

Model

 

Indoor unit 2

 

RAV-

SM802BT-E

 

 

 

 

 

 

 

 

Outdoor unit

 

RAV-

SM1603AT(Z)(ZG)-E

 

 

 

 

 

 

Cooling capacity

 

 

(kW)

14.0

 

 

 

 

 

 

Heating capacity

 

 

(kW)

16.0

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

Power supply

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

 

Running current

(A)

24.50 – 22.46

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

5.12

 

 

 

 

 

 

 

 

Cooling

Power factor

(%)

95

 

 

 

 

 

 

 

 

 

EER

 

2.73

 

 

 

 

 

 

Electrical

 

 

Energy efficiency class

 

 

 

 

 

 

characteristics

 

 

Running current

(A)

22.44 – 20.57

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

(kW)

4.69

 

 

 

 

 

 

 

 

Heating

Power factor

(%)

95

 

 

 

 

 

 

 

 

 

COP

 

3.41

 

 

 

 

 

 

 

 

 

Energy efficiency class

 

 

 

 

 

 

 

 

 

Fan

 

 

Centrifugal fan

 

 

 

 

 

 

 

 

Standard air flow

H/M/L

(m³/min.)

19.0 / 16.2 / 13.3

 

 

 

 

 

 

Fan unit

 

Motor

 

(W)

120

 

 

 

 

 

 

 

 

External

Standard (at shipment)

(Pa)

40

 

 

 

 

 

 

 

static pressure

Set up for tap exchange

(Pa)

20 / 40 / 70 / 100

 

 

 

 

 

 

 

 

Sound pressure level

H/M/L

(dB•A)

40 / 37 / 34

 

 

 

 

 

Sound power level

H/M/L

(dB•A)

55 / 52 / 49

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

Power supply

 

 

 

1 phase 230V (220 – 240V) 50Hz

 

 

 

 

 

 

 

 

Standard length

 

(m)

7.5

 

 

 

 

 

 

 

 

Min. length

 

(m)

5

Refrigerant

 

 

 

 

 

 

Max. total length

 

(m)

50

pipe

 

 

 

 

 

 

 

 

 

Height

Outdoor lower

(m)

30

 

 

 

 

 

 

 

difference

Outdoor higher

(m)

30

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

Propeller fan

 

 

 

 

 

 

Fan unit

 

Standard air flow volume

(m³/min.)

103

 

 

 

 

 

 

 

 

Motor

 

(W)

100 + 100

 

 

 

 

 

 

 

 

Gas side

Main

(mm)

15.9

 

 

 

 

 

Connecting

 

Sub

(mm)

15.9

 

 

 

 

 

 

 

pipe

 

Liquid side

Main

(mm)

9.5

 

 

 

 

 

 

 

 

 

Sub

(mm)

9.5

 

 

 

 

 

 

 

 

Sound pressure level

Cooling/Heating

(dB•A)

51 / 53

 

 

 

 

 

Sound power level

Cooling/Heating

(dB•A)

68 / 70

 

 

 

 

 

 