Toshiba RAV-SM1403DT-A, RAV-SM1603DT-A How to replace the sensor, 139, Work procedure

Models: RAV-SM1403DT-A RAV-SM1603ATZ-E RAV-SM1603ATZG-E RAV-SM1603DT-A

1 157
Download 157 pages 61.3 Kb
Page 139
Image 139
6. How to replace the sensor

6. How to replace the sensor

No.

Work procedure

Explanatory drawing

1As same as the work procedure of the fan motor

replacing, remove the right side plates (1) and (2).

Right side plate (2)

Right side plate

(1)

2Remove the shielding plate.

As the shielding plate is assembled with screws, take the fixing screws off to divide the plate.

Shielding plate

Shielding plate

3Cut the bunding band which ties 3 sensors together and then remove each sensor to replace them.

1)TC sensor

TC sensor can be mounted and fixed also by removing the sensor holder and inserting the sensor from the backward direction.

2)

TCJ sensor

TA sensor

 

TCJ sensor can be mounted and fixed by

 

(Suctioning surface)

 

entering the sensor into the sensor holder and

 

 

then push the holder including the sensor on

 

 

the pipes.

 

3)

TA sensor

TCJ sensor

(Red)

 

Remove TA sensor together with the holder

 

 

 

because the work space is narrow.

 

 

If remounting of the holder is difficult, direct the

 

 

sensor receiving part to the suction port and

TC sensor

 

then mount and fix the sensor to the pipes

 

using bunding band, etc.

(Black)

 

 

– 139 –