WM Configuration

Reflector Source

Push Receiver – The reflector is enabled and ready to receive a live

 

pushed stream.

 

 

Push Receiver

Informational. The complete address (IP address and port number) to

Address

which a stream can be pushed for reflecting.

 

 

Publishing Point

User-defined name. Must match the Encoder Push publishing point.

 

See Configuration: Encoder > Push on page 55.

 

 

Publishing Point

Check to enable. Default = Disabled. If enabled, you are prompted for

Authentication

Publishing Point User Name and Publishing Point Password.

 

 

Publishing Point

User defined. Must match Encoder Push user name if authentication is

User Name

enabled. See Configuration: Encoder > Push on page 55.

 

 

Publishing Point

User defined. Must match Encoder Push password if authentication is

Password

enabled. See Configuration: Encoder > Push on page 55.

 

 

Note The VBrick WM appliance supports pushing from a Microsoft WM Encoder. When setting up a push from a Microsoft WM encoder, the two steps are usually to configure the push, and then to start encoding which initiates a push to the network device. After configuring the push, the VBrick appliance will wait for up to 60 seconds for the push to begin. If you wait longer than 60 seconds to start encoding from the encoder, you may encounter an error similar to the following when trying to push to the VBrick appliance: The specified push template is invalid. Restarting the push will usually clear the error. Also, when you stop encoding, you may receive an error indicating: The

publishing point on the server is no longer available. This error occurs when the

encoder and the appliance are both shutting down and can be safely ignored.

Pull Receiver

The Pull option provides persistent pulling of an HTTP stream via a TCP connection from a VBrick appliance, a Microsoft encoder, or a Windows Media server. The source URL must contain the port number if the source is from a port other than port 80. If the URL contains a host name and not an IP address, the name will be resolved by the DNS server. Depending

VBrick WM Appliance Admin Guide