WM Configuration

URL

Valid path to a URL script file, for example: www.myserver.com/

 

config.xml. Default = blank.

 

 

Poll Rate

The rate at which the appliance checks the config file. 0–1440 minutes

 

(default = 0).

 

 

Auto Config Status

Shows auto config status including when the script was last run, URL

 

connection errors, etc. Press Refresh to update.

 

 

Run Script

Edit mode only. Run the script now.

 

 

Sample Script

The auto config script file (config.xml) is an .xml file with the following syntax. It can set any VBrick parameters and force an "apply" as needed. This example shows how to set various recorder parameters. Note that a VBEXECUTEFORCE tag is required.

<XML Header>

<?VBEXECUTEFORCE?> or <?VBEXECUTEIFDIF?> <VBRICK> vbrickHDRecorderControlMode = 1 vbrickHDRecorderControlIrEnable = 1 vbrickHDRecorderControlName = event1record.mpg vbrickHDRecorderControlDuration.value = 30 vbrickHDRecorderControlBatchEnable = 1 vbrickHDRecorderControlApplySet = 2 </VBRICK>

VBrick WM Appliance Admin Guide

87

Page 97